1Universidad Central de Chile, Faculty of Architecture, Urbanism and Landscape, Laboratorio de
Year: 2010
Type: article
Abstract: This paper presents the results of a study, commissioned by the Chilean Ministry of Education and UNESCO, of hygro-thermal comfort, visual comfort, acoustics and indoor air quality, as experienced in selected classrooms of 8 state schools located in distinct climatic zones in Chile.Using a post-occupancy evaluation methodology developed by the authors, 14 classrooms were evaluated with visual analysis, questionnaires and insitu measurements over a 5 day period.Although limited in its duration, the study clearly highlighted deficits in each of the areas of study; these included unacceptable sound pollution arising from transport; overheating due to excessive solar gain; insufficient heating and poorly insulated building fabric; poor indoor air quality; and poor day and electric lighting.
Authors: Armijo, Gabriela, Whıtman, Christopher, Casals, Roberto
Institution: Universidad Central de Chile
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze