Work

Untersuchung zur spezifischen Strahlenempfindlichkeit humaner Fibroblasten mit Röntgenstrahlung verschiedener spektraler Zusammensetzung

Year: 2014
Type: dissertation
Abstract: Background and aims: Examination techniques based on x-ray usage have been developing over the last few decades to diagnostic methods being fast, safe and reliable. But their harming effects on biological tissues are well known, too. According to that, legislative authority hasn’t set up any specification on energy dependent biological effectiveness of x-ray irradiation, although there is evidence of higher relative biological effectiveness at lower photon energies being proved by recent studies. The main aim of this dissertation was to evaluate the biological effectiveness of x-ray beams with different photon energies at equal doses. Methods: The key element of the process was to irradiate the cell samples at dose equivalent conditions. Dosimetry was difficult to manage due to very different x-ray spectrums (EPh,max = 30kV; 40kV; 130kV with filtered low energy proportion) and thereby unequal physical properties of mainly absorption conditions. Because of that dosimetry was set up with different techniques to combine each advantages of the particular method as well as to reduce systematic miscalculations. Both chemical and physical methods of dosimetry were used. In the end, there were also biological effects used as some kind of dose monitoring. On the one hand, four proteins of the DNA damage signal pathway were immunological marked; on the other hand, dose dependent colony building of human fibroblasts was observed. Results: Immunologic marking of double strand break indicators showed heterogenous results, which couldn’t prove clearly any dependence of biological effectiveness on the kind of x-ray irradiation. Likewise the colony building tests showed no significant change of survival fraction as a function of the applied x-ray spectrum. We have to admit restrictively that different dosimetric methods resulted in odd doses under equal irradiation conditions. According to that, keeping the specific advantages and disadvantages of different dosimetric methods in mind, we tried to achieve best dose equivalence under these conditions. Conclusion: There is no significant evidence proving that lower acceleration voltages like 30kV or 40kV result in elevated biological effectiveness of x-ray beams in contrast to 130kV. According to other publications our results differ from those. Maybe different dosimetric methods interfere with the different physical properties resulting in those different findings.
Author: Miederer, Alexander Frank
Language: German
Field: Medicine
Open Access status: green
OpenAlex ID: W7062982955
Cites: 33
Cited by:
Related to: 10