AI‑Enhanced Smartwatch AHI Estimation and AI‑Scored Polysomnography for Obstructive Sleep Apnea: Real‑World Validation
Year: 2025
Type: article
Abstract: Donghyeok Kim,1 Jeong Yup Han,2 Hyunjun Jung,2 Da Yeun Song,1 Changhee Lee,1 Gwanghui Ryu,1 Sang Duk Hong,1 Hyo-Yeol Kim,1 Yong Gi Jung1,3 1Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea; 2Mobile eXperience, Samsung Electronics, Suwon, Gyeonggi, Republic of Korea; 3Department of Data Convergence and Future Medicine Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of KoreaCorrespondence: Yong Gi Jung, Department of Otorhinolaryngology-Head and Neck Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Gangnam-gu, Seoul, 06351, Republic of Korea, Tel +82-2-3410-3579, Fax +82-2-3410-3879, Email [email protected]: This study validated the accuracy of an artificial‑intelligence (AI) smartwatch algorithm that directly estimates the apnea–hypopnea index (AHI) by comparing its performance with AI-scored Level 1 polysomnography (PSG) in Korean adults. The model was trained in South‑American cohorts, allowing inter‑ethnic validation.Methods: A total of 90 adults underwent simultaneous Level 1 PSG and smartwatch recording. Fifty‑three datasets with ≥ 3 hours of valid watch data were analyzed. AHI values were obtained as follows: expert‑scored PSG (pAHI), AI‑scored PSG (aiAHI), and smartwatch output (eAHI). Agreement was assessed with Spearman correlation, intraclass correlation coefficients, and receiver‑operating‑characteristic curves.Results: eAHI correlated strongly with aiAHI (ρ = 0.88, ICC = 0.87) and pAHI (ρ = 0.85, ICC = 0.82). For detecting moderate‑to‑severe OSA (aiAHI ≥ 15 events/h), the smartwatch algorithm yielded 92.3% sensitivity, 92.6% specificity, and 92.5% overall accuracy. Bland–Altman analysis revealed systematic underestimation of actual AHI by the smartwatch, particularly in mild OSA.Conclusion: This study demonstrates that the evaluated smartwatch-based AHI estimation algorithm shows high concordance with PSG-derived values, particularly for the detection and classification of moderate to severe OSA. However, it should be noted that this smartwatch algorithm tends to underestimate the AHI of OSA due to limitations in scoring unit and recording duration calculation. These findings support the clinical utility of wearable technology as a practical and scalable tool for early identification and longitudinal monitoring of OSA in real-world environments, while highlighting the need for further optimization to accurately detect mild cases.Keywords: sleep apnea syndromes, polysomnography, wearable electronic devices, artificial intelligence
Authors: Kim D, Han JY, Jung H, Song DY, Lee C, Ryu G, Hong SD, Kim HY, Jung YG
Language: English
Subfield: Physiology
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7084195382
FWCI:
Cites:
Cited by:
Related to: