Comparison of Four Lens Power Formulas for Sutureless Scleral-Fixated Carlevale Lens
Year: 2025
Type: article
Abstract: Agnieszka Dyrda,1,2 Liliana Araujo-Diaz,1 Amanda Rey,1 Maria S Pighin,1 Marta Pazos,3 Ignasi Jürgens1 1Institut Català de Retina, Barcelona, Spain; 2Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona (UB), Barcelona, Spain; 3Department of Ophthalmology, Hospital Clínic de Barcelona, Universitat de Barcelona (UB), Barcelona, Spain; Institut d’Investigacions Mèdiques August Pi i Sunyer (IDIBAPS), Barcelona, SpainCorrespondence: Agnieszka Dyrda, Institut Català de Retina, Ganduxer 117, Barcelona, 08022, Spain, Tel +34 93 378 23 19, Fax +34 93 418 78 57, Email [email protected]: To assess the predictability of intraocular lens (IOL) power calculation formulas for sutureless scleral fixation (SSF) of the Carlevale IOL.Methods: A prospective, single-center, interventional case series was conducted to compare predicted refractive outcomes using the SRK/T, Barrett II, Hoffer Q, and Holladay 1 formulas in patients undergoing SSF of the Carlevale IOL. The main outcomes included mean prediction error (PE), median absolute error (MedAE), mean absolute error (MAE), and the percentage of eyes with a PE within ± 0.50 and ± 1.0 diopters (D).Results: Sixty-nine eyes of 69 patients were included. Only the Barrett II formula resulted in a systematic myopic error (p=0.014). The PE of SRKT, HofferQ, and Holladay 1 was closer to 0, indicating that the post-operative refractive outcome was nearer to the predicted value than that of Barrett II (p=0.002, p< 0.001, p=0.003, respectively). MedAE and MAE ranged from 0.41 to 0.53 D and 0.6 to 0.67 D, respectively, without significant differences between the formulas. The percentages of eyes with PE within ± 0.50 and ± 1.00 D varied from 47.8 to 56.5% and 79.7 to 87%, respectively, showing no significant differences across the assessed formulas.Conclusion: The SRK/T, Hoffer Q, and Holladay 1 formulas provide favorable refractive outcomes for the SSF of Carlevale IOL. The Barrett II formula is less accurate and is not recommended due to its systematic myopic refractive error.Keywords: Carlevale IOL, sutureless scleral fixation, IOL power formula, refractive results, refractive prediction error
Authors: Dyrda A, Araujo-Diaz L, Rey A, Pighin MS, Pazos M, Jürgens I
Language: English
Subfield: Ophthalmology
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7084626906
FWCI:
Cites:
Cited by:
Related to:
