Work

Distensibility of the Human Eye

Year: 1959
Type: article
Abstract: TiE relationship between changes in pressure and changes in volume within the eye is of practical importance in the calibration of tonometers and in tonographic calculations, and the coefficient of ocular rigidity, K, proposed by Friedenwald (1937) has been employed generally for these purposes. Contrary to Friedenwald's assertion, it has been found that this coefficient is not a constant, but varies with intra-ocular pressure in the eyes of rabbits (Perkins and Gloster, 1957a, b) and of cats (Macri, Wanko, Grimes, and von Sallmann, 1957). In both species, the values of K increased markedly as the intra-ocular pressure increased. In view of these findings, it is of considerable importance to determine whether the coefficient of rigidity of human eyes is similarly dependent upon the intra-ocular pressure. Little attention has been given to this matter, although MacDonald (1955) produced some tonometric evidence which suggested that scleral rigidity was inversely related to intra-ocular pressure in living human eyes, and McBain (1957) reported that the rigidity of enucleated human eyes decreased as the intra-ocular pressure increased. Our observations, which have already been described briefly (Gloster, 1957), are in general agreement with the above findings and this paper gives a fuller account of our results. Methods Two methods for determining ocular rigidity were used-the "volumetric" method (Perkins and Gloster, 1957a) and the tonometric method (Perkins and Gloster, 1957b), the latter being quite distinct from the usual differential tono-metric method using two weights, which was found to be completely unreliable. Only dead human eyes have been studied, as both methods necessitate the intro-duction of a needle into the anterior chamber. Some of the measurements were made on eyes which had been rejected for use in corneal grafting and stored at 4 ° C. for 5 to 15 days after enucleation. Other determinations were carried out on cadaver eyes, in situ, between 8 and 14 hours after death. The experiments may be divided into three groups: (A) Enucleated eyes (three); studied by the volumetric method. (B) Enucleated eyes (four); rigidity determined by the tonometric method. (C) Dead eyes in situ (four); studied by the tonometric method.
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: bronze
OpenAlex ID: W1993126734
FWCI: 10.9
Cites: 5
Cited by: 30
Related to: 9