Work

Improvement of transverse beam size measurement using synchrotron radiation at Siam Photon Source

Year: 2025
Type: conference-paper
Abstract: The Siam Photon Source (SPS) has, for several decades, implemented direct imaging with synchrotron radiation for the measurement of transverse beam size. This paper describes improvements made to the transverse beam measurement system of the SPS storage ring. A synchrotron radiation interferometer system will be integrated for monitoring of beam size alongside the direct imaging system. The system's operations will be controlled and displayed through Python programming. The results from each technique will be comparatively analyzed.
Source: JACOW
Authors: Promdee,Wanisa, Suradet,Natthawut, Sudmuang,Porntip, Jummunt,Siriwan, Suebka,Surakawin, Pulampong,Thapakron
Language: English
Open Access status: hybrid
OpenAlex ID: W7104255517
FWCI:
Cites:
Cited by: