Transformer-based deep learning model for predicting fNIRS short-channel signals.
Year: 2025
Type: article
Abstract: Significance Functional near-infrared spectroscopy (fNIRS) enables portable and noninvasive monitoring of cerebral hemodynamics, but hemodynamic changes originating from extracerebral tissues may influence the signals. To avoid this, short-channel regression (SCR) is widely used, yet physical short-separation detectors are not always available or optimally positioned due to hardware limitations or the experimental setup. In such cases, a virtual, data-driven alternative to physical short-channel detectors may be a viable solution. Aim We aimed to (i) develop a transformer-based deep learning model to predict short-separation optical density (OD) signals from long-separation channels and (ii) evaluate whether these virtual signals enable effective SCR. Approach We trained the model on a resting-state fNIRS dataset (69 subjects) with paired short- and long-separation recordings. Dual-wavelength OD signals in segmented time windows were used as input for a transformer encoder trained to reconstruct the extracerebral hemodynamic component measured by short channels. Model performance was evaluated using 3 independent datasets: a holdout subset of the same resting-state dataset (23 subjects), a second dataset acquired using a different system (40 subjects), and a task-based finger-tapping dataset (4 subjects). A wavelet coherence-based channel rejection step was optionally applied during preprocessing. Predictions were evaluated using signal similarity metrics (mean squared error [MSE], normalized MSE [NMSE], and Pearson correlation [ r ]) and denoising efficacy (residual variance after regression). Results Predicted short-channel signals showed high correspondence with ground-truth measurements in OD (median r = 0.70 and NMSE = 0.047 ) and concentration data (up to r = 0.67 ). When used for SCR, virtual regressors effectively denoise long-channel data. Performance was robust across all datasets, with greater accuracy when low-coherence channels were excluded. In motor task blocks, predicted regressors preserved task-evoked activations and reduced residual variance. Conclusion Transformer-based models accurately reconstruct extracerebral hemodynamic signals from long-separation fNIRS data, providing a virtual alternative to physical short channels and supporting standardized, hardware-independent preprocessing.
DOI: 10.48620/92485
Authors: Guglielmini, Sabino, Banchieri, Vittoria, Scholkmann, Felix, Wolf, Martin
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7106322930
FWCI:
Cites:
Cited by:
Related to: