Vacuum monitoring and controls acceptance testing for LCLS-II HE cryomodules at SLAC
Year: 2025
Type: conference-paper
Abstract: The LCLS-II High Energy (LCLS-II HE) upgrade at SLAC National Accelerator Laboratory involves the delivery and long-term storage of superconducting cryomodules, manufactured at partner laboratories and shipped to SLAC. To maintain their performance, these cryomodules must preserve ultra-high vacuum (UHV) conditions prior to installation. Upon arrival, each unit undergoes a comprehensive controls acceptance test to validate instrumentation functionality, including sensor accuracy, signal integrity, and system connectivity. To ensure vacuum integrity during extended storage, a vacuum monitoring system was developed to continuously track cold cathode gauge pressure, integrated into the EPICS control system for real-time data, alarms, and archiving. Despite using a single gauge per cryomodule, the system enables early detection of vacuum degradation with minimal hardware. This paper outlines the acceptance testing, vacuum monitoring system design, and operational experiences, along with data trends, alarm scenarios, and lessons learned to improve future cryomodule storage practices.
Source: JACOW
Authors: Chillara,Rohini Sri Priya, Wilson,Andrew, Lai,Chinh Duc, White,Dominique A, Saraf,Shweta, Huang,Ziyu
Language: English
Subfield: Aerospace Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
OpenAlex ID: W7109057076
FWCI:
Cites:
Cited by:
Related to: