Kasviplanktonlevien lipidimäärän arviointi Nile red -fluoresenssimerkkiaineen avulla
Year: 2012
Type: dissertation
Abstract: To make the biodiesel production process with phytoplankton feasible, the intracellular neutral lipids need to be detected rapidly during cultivation. This master's thesis concentrated on a neutral lipid quantification method utilizing a fluorescent dye Nile red that penetrates the phytoplankton cell wall and stains the lipids. The first aim of this study was to find out, whether the Nile red penetration into phytoplankton cells and subsequent lipid staining of the neutral lipids could be enhanced with the use of solvents in the case of phytoplankton species that have been proven difficult to stain. The second aim of this study was to evaluate, whether the Nile red method is plausible for automated in situ lipid quantification of neutral lipids in phytoplankton. The overall aim was to evaluate, whether it would be possible to standardize the Nile red staining method. The effect of solvents on the Nile red penetration was tested on four promising phytoplankton strains for biodiesel production: Phaeodactylum tricornutum TV335, Scenedesmus obliquus TVK-SOB-1, Chlorella pyrenoidosa TV216 and Isochrysis sp. CCAP 927/12. Three different solvents (i.e., DMSO. ethylene glycol and glycerol) were chosen for the experiment. The effect of the solvents on Nile red penetration into the cells in different growth phases was observed by kinetic fluorescence measurements. The Nile red fluorescence values were compared to the true total lipid contents determined gas chromatographically. The automation experiment was carried out with P. tricornutum TV335. To see, whether it is possible to automate the Nile red method with a flow injection analysis (FIA) system a modified Nile red method was experimented. All the solvents increased the Nile red fluorescence values of P. tricornutum. None of the solvents enhanced the penetration of Nile red into the S. obliquus and C. pyrenoidosa cells. The Isochrysis sp. cells stained best practically without solvents. The modified Nile red method with P. tricornutum produced similar results as the traditional method and turned out to be very plausible for automation. Overall, the results of this study strongly indicated that the parameters of the Nile red method cannot be standardized but need to be determined separately for every species. Neither can universal recommendations be given for staining of specific species. Nevertheless, the Nile red method definitely has potential to become an effective neutral lipid quantification method for the industry and research.
Source: Aaltodoc (Aalto University)
Author: Natunen, Katariina
Language: English
Field: Energy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7111684746
