Year: 2024
Type: dissertation
Abstract: Cardiovascular diseases are on the rise in the modern world, with Coronary Artery Disease (CAD), predominantly caused by atherosclerosis, leading the way.Atherosclerosis hampers blood flow to the heart muscle, resulting in myocardial ischemia and often culminating in a heart attack (myocardial infarction).Timely diagnosis and treatment, including appropriate revascularization of the coronary artery, are therefore crucial to preventing serious health outcomes for patients.A number of methods have been developed to diagnose and monitor CAD, with the invasive measurement of Fractional Flow Reserve (FFR) being widely recognized as the gold standard for assessing the functional significance of coronary artery stenosis.However, despite its effectiveness, this invasive approach has certain drawbacks, such as the risk of vascular injury, the need for vasodilation and substantial medical costs.This underscores the need for a reliable, non-invasive diagnostic method that can provide timely and accurate results without subjecting patients to unnecessary risks.Computational Fluid Dynamics (CFD) offers a non-invasive solution by determining FFR through digital processing of angiographic images to create a three-dimensional (3D) model of the stenosed coronary artery.However, CFD models are time-consuming and demand considerable computational resources.The objective of this doctoral dissertation was to develop an alternative analytical approach that is less resource-and time-intensive but still capable of generating a 3D model of the coronary artery based on angiographic images.Unlike CFD methods, this approach calculates FFR by applying the fundamental principles of fluid dynamics.All energy losses in the stenosed coronary artery were identified and meticulously analysed using well-established principles from the literature.The FFR value was then determined by calculating the total pressure drop and using the known pressure value in the aorta.The proposed analytical method was validated against clinical data from 62 patients who had undergone invasive coronary angiography and was also compared with results obtained from CFD simulations using the PAK-F solver developed at the Faculty of Engineering in Kragujevac.The findings demonstrated that the FFR calculated by the analytical method showed a good correlation with both the clinical data and the CFD results.This confirms that the FFR determined by the model proposed in this dissertation can serve as a reliable parameter for the physiological assessment of coronary artery stenosis.
Author: Milovanović, Aleksandar
Institution: University of Kragujevac
Language: Serbian
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7112777146
