Optimized ultrasound imaging of phase-change nanodroplets
Year: 2025
Type: article
Abstract: • Activation transmit parameters influence uniformity and size of droplet activation. • Spacing and order of transmits affect gap size, cavitation, and acquisition time. • ROI optimization increases contrast while reducing acquisition time and bioeffect risks. • Nonlinear relationship exists between droplet concentration and ultrasound signal. • Harmonic-to-linear ultrasound signal ratio depends on droplet concentration. Phase-change nanodroplets (PCNDs) continue to generate significant research interest due to their potential to extravasate into tissue, to be targeted for molecular imaging and drug delivery, and to undergo an induced phase-change to “activated” microbubbles (MBs) for ultrasound (US) imaging. To accurately quantify molecular markers, however, one assumes a consistent proportion of PCNDs in a region of interest (ROI) are stably activated and imaged. Herein we present a framework for developing a diagnostic sequence that is optimized for PCND activation uniformity, contrast, and acquisition time. To develop this framework, activation was examined in three scales of increasing complexity: single, adjacent, and full ROI activation(s). First, transmit parameters for a single activation were optimized using PCNDs across concentrations (1.0 × 10 7 –10 9 PCND/mL) in controlled phantom experiments, considering contrast-to-noise ratio (CNR), area, and offset (e.g., centroid axial distance from transmit focus) of the activation region along with acquisition time. Activation regions were also compared to prospective estimates based on US-beam imaging. Next, overlap and order of adjacent activation regions was optimized by maximizing spacing while preserving uniformity and minimizing signal loss from adjacent transmit interactions. Finally, an optimized raster-scanning scheme was applied to a mock tumor ROI, yielding 1.4–7.0 dB greater contrast enhancement over unoptimized schemes while reducing acquisition time. Further, PCND concentration was found to share a nonlinear relationship with US signal enhancement that differed significantly between linear and harmonic imaging modes. In conclusion, our framework’s optimization of contrast, uniformity, acquisition time, and cavitation mitigation for PCND US imaging should help facilitate its eventual clinical translation.
Source: Ultrasonics
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $3,680
Awards: Ultrasensitive acoustic reporter proteins with engineered rupture-resistant shells, G4276892241, Molecular Photoacoustic Imaging for Diagnostics and Therapy Monitoring, Recruitment of First-Time, Tenure-Track Faculty Members, G5029162653, Recruitment of First-Time, Tenure-Track Faculty Members, G8174146425, Neoadjuvant Treatment Response Monitoring of Breast Cancer With Molecular Photoacoustic Imaging, G9000034222
OpenAlex ID: W7116442662
