Optimization of the Contrast Concentration for Low-Tube-Voltage Chest CT: A Randomized Controlled Trial with Low-Concentration Contrast Media
Year: 2025
Type: article
Study designs: Randomized Controlled Trial, Clinical Trial
Abstract: Objective: To evaluate the effect of low-concentration contrast media (LCCMs) on 100 kVp conventional chest CT by comparing the proportions of acceptable-quality scans obtained using various CM concentrations with those obtained using the standard protocol. Materials and Methods: This prospective, multicenter, randomized controlled trial enrolled adult patients with BMI < 30 who underwent enhanced chest CT between December 2023 and September 2024. Participants were randomly assigned to four groups: one control group (120 kVp, 320 mgI/mL) and three test groups using 100 kVp and standard CM (320 mgI/mL) or LCCMs (270 or 240 mgI/mL). Non-inferiority was tested based on the proportion of acceptable-quality scans independently assessed by two readers. Adverse reactions, including injection site pain and localized and systemic heat sensations, were recorded. Results: A total of 371 participants (mean age: 66.0, IQR: 58–73 years) were randomized. 100 kVp chest CT with LCCM groups showed non-inferior image quality to the standard protocol (270 mgI/mL: reader 1—98.33% confidence interval [CI]: −4.95, 9.37 and reader 2–98.33% CI: −7.11, 7.21; 240 mgI/mL: reader 1–98.33% CI: −6.44, 8.71 and reader 2–98.33% CI: −11.47, 5.11; all p < 0.001). Reader 2 reported a lower proportion of acceptable scans in the 320 mgI/mL low-voltage group (p = 0.11), whereas Reader 1 did not find significant inferiority (p = 0.003). Injection site pain, localized heat, and systemic heat were less frequent in LCCM groups, while systemic heat was only statistically significant (p = 0.003). Conclusions: Low-tube-voltage (100 kVp) chest CECT using LCCMs yields non-inferior image quality compared with the standard protocol while using conventional concentration contrast media under 100 kVp resulted in decreased proportion of diagnostically acceptable scans.
Source: Diagnostics
Institutions: The Catholic University of Korea Seoul St. Mary's Hospital, Catholic University of Korea, The Catholic University of Korea Bucheon St. Mary's Hospital, Chonnam National University Hospital, Jeonbuk National University Hospital, Jeonbuk National University, Pusan National University Yangsan Hospital, Pusan National University, Seoul National University
Language: English
Topic: Radiation Dose and Imaging
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W7117313205
