Assessing Change in Stone Burden on Baseline and Follow-Up CT: Radiologist and Radiomics Evaluations
Year: 2025
Type: article
Study design: Observational Study
Abstract: This retrospective diagnostic accuracy study compared radiologist-based qualitative assessments and radiomics-based analyses with an automated artificial intelligence (AI)–based volumetric approach for evaluating changes in kidney stone burden on follow-up CT examinations. With institutional review board approval, 157 patients (mean age, 61 ± 13 years; 99 men, 58 women) who underwent baseline and follow-up non-contrast abdomen–pelvis CT for kidney stone evaluation were included. The index test was an automated AI-based whole-kidney and stone segmentation radiomics prototype (Frontier, Siemens Healthineers), which segmented both kidneys and isolated stone volumes using a fixed threshold of 130 Hounsfield units, providing stone volume and maximum diameter per kidney. The reference standard was a threshold-defined volumetric assessment of stone burden change between baseline and follow-up CTs. The radiologist’s performance was assessed using (1) interpretations from clinical radiology reports and (2) an independent radiologist’s assessment of stone burden change (stable, increased, or decreased). Diagnostic accuracy was evaluated using multivariable logistic regression and receiver operating characteristic (ROC) analysis. Automated volumetric assessment identified stable (n = 44), increased (n = 109), and decreased (n = 108) stone burden across the evaluated kidneys. Qualitative assessments from radiology reports demonstrated weak diagnostic performance (AUC range, 0.55–0.62), similar to the independent radiologist (AUC range, 0.41–0.72) for differentiating changes in stone burden. A model incorporating higher-order radiomics features achieved an AUC of 0.71 for distinguishing increased versus decreased stone burdens compared with the baseline CT (p < 0.001), but did not outperform threshold-based volumetric assessment. The automated threshold-based volumetric quantification of kidney stone burdens provides higher diagnostic accuracy than qualitative radiologist assessments and radiomics-based analyses for identifying a stable, increased, or decreased stone burden on follow-up CT examinations.
Source: Journal of Imaging
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,172
OpenAlex ID: W7117455137