Work

Efeito da troca iônica nos parâmetros de Weibull, de crescimento subcrítico de trincas e no comportamento de curva R de uma porcelana odontológica

Year: 2007
Type: dissertation
Abstract: The objectives of this study were to determine the influence of different ion exchange (IE) temperatures on mechanical properties of a dental porcelain Ultrapaline ST and the effect of IE on slow crack growth (SCG) (coefficient of SCG - n, scale parameter - ?f0) and Weibull parameters (characteristic strength - ?0; Weibull modulus - m) and R-curve behavior of this porcelain. 250 specimens (12 mm diameter x 1 mm height) were fabricated according to the manufacturer\'s instructions, grounded with a surface-grinding device and polished up to 1?m. To determine the effect of IE temperature on biaxial flexural strength (?), hardness (H) and fracture toughness (KIc), 40 specimens were divided in four groups (n=10) as follow: GI - control (no ion exchange); GII, GIII and GIV submitted to IE with KNO3 for 15 min at 450°C; 470°C e 490°C, respectively. The ? was determined using a piston-on-three-balls device, in artificial saliva at 37°C and constant loading rate of 10 MPa/s. For hardness and fracture toughness, 3 Vickers indentations (2kg, 30s) were made on each specimen. The diagonals and radial cracks were measured in order to calculate H and KIc. Mean and standard deviations values of ? (MPa), H (GPa) and KIc (MPa.m1/2) were: I: 57.95 ± 8.97; 7.24 ± 0.79; 1.14 ± 0.14; II: 125.04 ± 23.58; 5.80 ± 0.14; 2.62 ± 0.14; III: 133.00 ± 11.00; 5.88 ± 0.45; 2.54 ± 0.22; IV: 137.67 ± 12.05; 5.88 ± 0.17; 2.57 ± 0.10, respectively. To determine the effect of IE on SCG and Weibull parameters, 140 specimens were divided in 2 groups: GC (control) and GIE (submitted to IE at 470°C for 15 min). To determine the SCG parameters, 10 specimens of each group were tested in biaxial flexural strength in each one of five constant stress rates: 10-2, 10-1, 100, 101 e 102 MPa/s. To determine the Weibull parameters, 20 specimens of each group were tested in the stress rate of 100 MPa/s. The n, ?f0, m and ?0 (values in parenthesis represent the confidence interval) were: 24.1 ± 2.5; 58.1 ± 0.01; 13.8 (10.0 to 18.8) and 60.4 (62.2 to 58.5) for GC and: 36.7 ± 7.3; 127.9 ± 0.01; 7.4 (5.3 to 10.1) and 136.8 (129.1 to 144.7) for GIE, respectively. To determine the effect of IE on R-curve behavior, 7 specimens of each group received a Vickers indentation in one of the following indentation loads (kg): 0.18; 0.32; 0.56; 1.0; 3.2. After stored on air for 24 h, the specimens were tested biaxial flexure strength in artificial saliva at 37°C in a stress rate of 10 MPa/s. The ?, ?, q parameters were, respectively: 62.57; 0.12 and 0.2857 for GC and 161.50; 0.34 and -0.0074 for GIE. The values of k varied from 0.371 to 0.515 for GC and from 0.34 to 0.0074 for GIE. There are no differences on mechanical properties among the three IE temperatures tested. The IE promoted significantly increase of n, ?f0 and ?0 however, decreased the m value and suppressed the R-curve behavior originally present on material before the IE.
Language: Portuguese
Field: Dentistry
Open Access status: green
OpenAlex ID: W1833035633
Cites: 75
Cited by: 2
Related to: 10