Avaliação de dessincronia atrioventricular em portadores de marca-passo bicameral devido à doença do nó sinusal e bloqueio atrioventricular de primeiro grau
Year: 2017
Type: dissertation
Abstract: BACKGROUND: Long PR interval and wide QRS duration duo to ectopic morphology generated by artificial cardiac pacing are associated with cardiac dysfunction and dyssynchrony at different levels. When programming a permanent pacemaker in sinus node disease, two strategies can be considered: long PR with narrow QRS (avoiding ventricular pacing despite the risk of losing atrioventricular syncrony) or optimized PR interval with pacemaker-induced wide QRS (aiming to correct the atrioventricular delay despite loss of the ventricular synchrony). In this study, we aimed to compare the clinical and cardiac structural outcomes of these two strategies. METHODS: Sudy a cohort of patients with sinus node disease, first-degree AV block (binodal disease) and DDD pacemaker was followed for 1 year follow-up. atrioventrucular synchrony (AVS) was assessed echocardiographically by the ventricular diastolic filling time on Doppler transmitral flow: sum of the duration of E and A waves >=40% of the cardiac cycle. Patients with AV dyssynchrony (AVD) had the AV delay optimized (intervention group) for the best hemodynamic performance, but under wide artificially paced QRS. These returned to baseline PR interval after 6 months (cross-over). Those with AVS were kept under intrinsic QRS throughout the follow-up period despiste long PR interval (control group). RESULTS: Forty-three patients were included (mean age = 71.5 years), and 41 completed the 1-year follow-up. The existence of the 2 groups was confirmed (p=263 ms had a specificity of 78.9% for the diagnosis of AVD, and longer PR intervals were associated with worse baseline ventricular systolic function. Most patients with AVD were men, had longer PR intervals (mean= 283.5 ms), and had significantly lower diastole duration (p= 0.032). A subgroup of AVD patients with PR >300 ms had poorer quality of life, significantly greater use of ?-blockers (p= 0.011), longer paced QRS width, and AV dyssynchrony that is non-correctable by optimization. Notably, at 6 months, the AVD group lean towards to have better LVEF values despite the wide QRS and a decrease when returning to baseline. Patients with AVS also had PR intervals different from the physiological condition (157.9 to 330 ms) and, over time, had worsening of mitral regurgitation (p=0.008) and earlier atrial fibrillation. PR>263 ms (RR= 1.84; p= 0.024) and diastole duration
Author: Andres Di Leoni Ferrari
Institution: Universidade de São Paulo
Language: Portuguese
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W2768027742