Análise do jitter com agulha concêntrica em pacientes com miastenia gravis autoimune adquirida
Year: 2016
Type: dissertation
Study design: Observational Study
Abstract: INTRODUCTION: Single fiber electromyography (SFEMG) technique, through jitter analysis, is the most sensitive neurophysiological method for confirmation of neuromuscular junction disorder in myasthenia gravis (MG). Records are traditionally obtained with single fiber needle, which is reusable and has a high-cost. Due to the current need of using disposable material, concentric needle has been used to replace single fiber needle. The technique is similar, but the action potential for jitter analysis is obtained with concentric needle electrode (SFEMG - concentric needle jitter, SFEMG-CNJ). However, studies are scarce and methodologies used are heterogeneous with the use of this needle. OBJECTIVES: This study aims to measure jitter values obtained with concentric needle in the Orbicularis Occuli muscle in healthy subjects and in patients with autoimmune acquired MG and to assess the validity of the method in generalized and ocular forms of the disease. METHODS: 20 healthy subjects, 20 patients with generalized myasthenia gravis (GMG group) and 13 with the ocular form of the disease (OMG group) were studied. SFEMG-CNJ was performed on all participants, ideally with 20 jitter values in each study. Jitter was expressed as the mean consecutive difference (MCD). Repetitive nerve stimulation and serum acetylcholine receptor antibody (AChR-ab) were performed in all patients in the study, by the time of jitter analysis. Tyrosine kinase specific antibody muscle antibodies (MuSK-ab) were performed in AChR-ab negative patients. The upper limit of normality (ULN) for the mean MCD and for individual jitter values were defined. The abnormality criteria were: (1) mean MCD above ULN; or (2) more than 10% of individual jitter values above ULN. The definition of ULN for individual jitter values was based on the concept that two out of 20 jitter values above ULN are acceptable in a healthy muscle for voluntary contraction technique. Therefore, the ULN for the 18th highest jitter value (18 pair) was estimated. To analyze the method\'s accuracy, two ROC curves (Receiver Operating Characteristic) for the mean MCD and 18th pair in the group of patients (MGG and MGO) versus control were constructed. RESULTS: In the control group the mean of MCD means was (19.0 ± 2.4)us and the mean of the 18 highest value of each study was (24.5 ± 3.6)us. These values showed Gaussian distribution and the ULN was set as the mean of these values + 2 SD. The ULN for the mean MCD was 24us, and 32us for individual values of MCD. In GMG group, jitter analyses were abnormal in all 20 patients based on both abnormality criteria, except in one patient, who had abnormalities in only one of the criteria. In OMG group, only one patient from 13 met neither of the abnormality criteria. In patients, the positivity of SFEMG-CNJ was higher than repetitive nerve stimulation test and antibody detection. The ROC curve threshold showing the best sensitivity (93.9%) with no false positive results was 24.7Us for the mean MCD and 33.1us for individual pairs, respectively. CONCLUSIONS: SFEMG-CNJ has high sensitivity and specificity in identifying neuromuscular transmission disorder in patients with MG. The use of concentric needle is valid for jitter analysis as an alternative to single fiber needle
Author: Flavia Costa Nunes Machado
Institution: Universidade de São Paulo
Language: Portuguese
Subfield: Clinical Neurology
Field: Medicine
Domain: Health Sciences
Open Access status: green
Funder: Universidade de São Paulo
OpenAlex ID: W2515935236