Work

Influência da infraestrutura urbana nas águas subterrâneas na cidade de Urânia (SP)

Year: 2022
Type: dissertation
Abstract: Detections of nitrate in the groundwater in the city of Urania has been reported since the late 1990s, still showing high levels of concentrations (>422mg/l-NO3) even after installing sanitation system. This interaction is commonly found in urban settlements, and it is difficult to quantify. Thus, this work identified and related the urban growth patterns of water and sewage leakages in the municipality of Urânia (SP), applying different methods such as supply water and wastewater mass balance; isotopic mass balance (\'delta\' 18O and \'delta\'D); hydrogeological and hydrogeochemical characterization focused on nitrogen. Results showed that the denitrification is not a relevant process in the aquifer. (1) concentrations below the detection limit of dissolved organic carbon (DOC) and total carbon (TC), low levels of 15N-NO3 enrichment, (between 8 and 12), presence of dissolved oxygen (DO) (more than 2 mg/l O2) and intermediate redox conditions; and (2) a presence of a sandstones layer with mud and carbonate cementation below 50m of depth gives it low hydraulic conductivity that imposes preferably horizontal, superficial flow. Therefore, the absence of a plume at depth more than 70 m is rather due to hydraulic than biogeochemical factors with an impact restricted to the shallower (ZR, up to 30 m) and intermediate (ZI, 30 m - 70 m) zones. Additionally, rNO3/Cl shows different pattern of nitrate concentrations in each sector and can be related to the history of urban occupation. The sewage leakage coefficient was estimated to be between 8% and 12%. The average value for urban recharge was approximately 129,000 m3/year (0.044 m/a); 66,000 m3/year for the water supply network and 63,000 m3/year for sewage. Natural recharges add another 48,000 m3 /year, so human urban recharge is estimated at three times the natural recharge. The sewage system leak generated a load of 7.3 to 19.3 ton/year of nitrate. This contaminant load has been sufficient to keep the nitrate contaminant plume stable. The comparison of the isotopic signatures of \'delta\'18O and \'delta\'D of the water from the public network and the sewage indicated, in addition, that the use of private wells that extract water from the Adamantine Aquifer is still significant to meet the demand.
Language: Portuguese
Open Access status: green
OpenAlex ID: W4297665030
Cites: 125
Cited by: 2
Related to: 8