Validade e confiabilidade da ressonância magnética para o diagnóstico da rotura do tendão do subescapular
Year: 2018
Type: dissertation
Abstract: INTRODUCTION: The accuracy of magnetic resonance imaging (MRI) for the detection of subscapularis tear presents wide variation in the literature. There are few prospective studies and great methodological variation. It is believed that these tears are more difficult to diagnose than the posterosuperiores rotator cuff injuries. The subscapularis tendon has importance in the biomechanics in the shoulder and its rupture leads to functional impairment. A diagnostic tool of good accuracy is fundamental in clinical practice, influencing prognosis and surgical planning. The aim of this study was to evaluate the validity of preoperative MRI in the identification of the subscapularis tears, comparing the imaging findings with the intraoperative data of arthroscopic surgery. As a secondary objective, we evaluated the reliability of the method through interobserver and intraobserver agreement. METHODS: We performed a diagnostic accuracy study comparing MRI findings (index test) with those of arthroscopy (reference test), in a prospective cohort. We included patients submitted to arthroscopy for the treatment of rotator cuff tears that had undergone high magnetic field MRI without using contrast. Cases of previous surgical manipulation in the shoulder, exams with moving artifacts, indication for open surgery and interval between MRI and surgical procedure of more than one year were excluded. The images were evaluated by a shoulder surgeon and two musculoskeletal radiologists, independently and blinded to the results of arthroscopy, being reassessed after 3 months by the surgeon. We calculated the validity (sensitivity, specificity, positive predictive value, negative predictive value and accuracy) and reliability (inter- and intraobserver agreement) of MR in detecting subscapularis tears. RESULTS: We evaluated 200 shoulders. The incidence of subscapularis tears was 69.5% (41.5% partial and 28.0% transfixing). The shoulder surgeon showed sensitivity from 51.1 to 59.0% and specificity from 91.7% to 94.4%. The radiologists, 83.5 to 87.1% of sensitivity and 41 to 45.9% of specificity. Accuracy ranged from 60.5 to 73.0%. The mean values of sensitivity, specificity and accuracy were 70.2%, 61.9% and 67.6%, respectively. Interobserver agreement was moderate for the detection of subscapular tears (kappa coefficient 0.463, 95% CI 0.383-0.534, p < 0.001), as well as intraobserver agreement (kappa coefficient 0.546, 95% CI 0.430-0.662, p < 0.001). Patients with subscapular rupture had a higher incidence of biceps rupture and instability, greater fat subscapular degeneration, and higher mean age. The other variables did not present statistically significant differences. CONCLUSION: MRI of high magnetic field without contrast showed mean values of sensitivity, specificity and accuracy of 70.2%, 61.9% and 67.6%, respectively. Sensitivity was higher in radiologists while specificity in the shoulder surgeon. Interobserver and intraobserver agreement was moderate
Author: Lucas Busnardo Ramadan
Institution: Universidade de São Paulo
Language: Portuguese
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Keywords: subscapularis tear, rotator cuff tear, magnetic resonance imaging, diagnostic accuracy, arthroscopic surgery, interobserver agreement, intraobserver agreement, sensitivity and specificity, shoulder arthroscopy, partial-thickness tear, shoulder biomechanics, shoulder impingement syndrome, shoulder weakness, shoulder range of motion
Open Access status: green
OpenAlex ID: W2908175958