Abstract: Unpredictable fetal motion during MRI scans can result in oblique 2D slices that are difficult to interpret and often leads to prolonged scan times. Slice-to-volume reconstruction (SVR) methods align 2D oblique slices from multiple slice stacks into a coherent 3D volume. We propose a convolutional network that predicts slice poses by performing multiscale, unrolled optimization and further refines them and super-resolves the volume using model-based optimization. Our convolutional feed-forward SVR network achieves accuracy on par with state-of-the-art results while offering significant speedup, paving the way for scanner-side use of SVR. The code is available https://github.com/MedicalVisionGroup/cSVR.
Source: arXiv
Institutions: MIT Computer Science and Artificial Intelligence Laboratory, Massachusetts Institute of Technology, Harvard University, Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Children's Mercy Hospital, University of Missouri–Kansas City, Boston Children's Hospital