Impending erosion of penile prosthesis pump: Salvage management with pseudo-capsule excision and median raphe repositioning – A case report
Year: 2026
Type: article
Study design: Case Report
Abstract: Pump erosion is a rare complication of penile prosthesis implantation that often requires explantation. We present a 43-year-old diabetic male who developed impending pump erosion with scrotal skin thinning over a functional prosthesis pump. Salvage was performed by excision of the fibrotic pseudo-capsule and relocation of the pump into the median raphe, combined with antibiotic and antifungal irrigation. The patient recovered uneventfully with excellent cosmetic and functional outcomes. This case highlights pseudo-capsule excision and median raphe repositioning as a safe, effective salvage option in selected patients without infection.
Source: Urology Case Reports
Author: Mohammad K. Khan
Language: English
Subfield: Psychiatry and Mental health
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $1,160