Work

Results of HESR BPM Testing

Year: 2026
Type: conference-paper
Abstract: For the HESR diagonally cut BPMs were designed, with 64 manufactured and tested with a purpose-built BPM test-stand. This test-stand had to host BPMs of various lengths, the overall length of the complete vacuum system varies from 450 mm to 1585 mm. For all BPMs several properties, e.g. the geometric factors or the electrical center in relation to the geometric center, were measured utilizing the test stand. The results of these measurements will be presented together with the challenges resulting from the design choices made for the layout of the test stand.
Source: JACOW
Language: English
Open Access status: hybrid
OpenAlex ID: W7124901983
FWCI:
Cites:
Cited by:
Related to: