Spray Coating Oxidized Graphene-Based Materials Makes Polyurethane Surfaces Antibacterial and Biocompatible: A Promising Approach for Medical Devices
Year: 2026
Type: article
Abstract: High Resolution Image Download MS PowerPoint Slide Preventing bacterial infections remains a primary concern for healthcare systems and patients. Polyurethane (PU) is widely used in various invasive medical devices, improving PU surfaces─particularly by reducing bacterial adhesion─a highly sought-after goal. This study explores the spray coating of PU-based medical devices with oxidized graphene-based materials (GBMox) as antibacterial agents, specifically oxidized graphene nanoplatelets (GNPox) and graphene oxide (GO). Different formulations, with and without PU as a coating binder, were investigated to assess the potential for tuning the coating based on the intended application. The resulting coatings were characterized in terms of morphology using Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM), along with wettability and stability analysis. Antibacterial activity was evaluated against Staphylococcus epidermidis, with GNPox-containing coatings reducing bacterial adhesion by up to 82%, with no effect from blood plasma proteins. In vitro biocompatibility was confirmed across all surfaces: human fibroblasts adhered and spread on coatings without PU, while coatings combining GNPox and PU retained the low cell adhesiveness typical of PU. Overall, GBMox coatings on PU enhance antibacterial performance, preserve biocompatibility, and enable tuning of the cell adhesion behavior. These coatings offer a promising antibiotic-free strategy for PU-based biomedical applications, and the spray coating method provides a simple, reproducible, and industrially scalable approach.
Authors: Natacha Rosa, Inês Borges, Patrícia C. Henriques, Andreia T. Pereira, Rita N. Gomes, Fernão D. Magalhães, Inês C. Gonçalves
Language: English
Subfield: Biomedical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $4,500
Awards: G1172344086, G1920279751, G198576669, ALICE - Laboratório Associado em Engenharia Química, G419255200, Laboratório de Engenharia de Processos, Ambiente, Biotecnologia e Energia, G5417456410, Designing composite biomaterials for antimicrobial hemodialysis catheters, Laboratório de Engenharia de Processos, Ambiente, Biotecnologia e Energia, G5963377275, UID/BIM/04293 .: Instituto de Investigação e Inovação em Saúde, Novos biomateriais para prevenção de infecção associada a cateteres de diálise, G6997928969, G7121740766, Qualidade e Segurança Alimentar — uma abordagem (nano)tecnológica, UID/EQU/00511 .: Laboratório de Engenharia de Processos, Ambiente, Biotecnologia e Energia
OpenAlex ID: W7124913062
