A rare double Maisonneuve fracture involving concurrent proximal and distal fibula; Weber type A fracture: A case report
Year: 2026
Type: article
Study design: Case Report
Abstract: Double Maisonneuve fracture is an extremely rare traumatic condition characterized by simultaneous proximal and distal fibular fractures with syndesmotic disruption. Previously reported cases involved only Weber type B or C distal fibular fractures. To date, no reports have described an associated Weber type A fracture. We report a case of a double Maisonneuve fracture involving a Weber type A distal fibular fracture and describe the clinical course and surgical management. A 63-year-old man sustained a left lower leg crush injury involving a Weber type A distal fibular fracture, proximal fibular fracture, medial and posterior malleolar fractures, and tibiofibular diastasis. After initial external fixation, definitive internal fixation was performed on postoperative day 9. The Weber type A fracture was treated using nitinol staples, and fibular length restoration was achieved with a foot distractor. The ankle mortise was stabilized using a one-third tubular plate and trans-syndesmotic screws. Postoperative imaging confirmed adequate fracture reduction and restoration of the ankle mortise. One year after surgery, radiographs and CT showed complete union and maintained syndesmotic alignment. The patient achieved a Japanese Society for Surgery of the Foot (JSSF) score of 90/100, with full range of motion in both the knee and ankle. Double Maisonneuve fracture with a Weber type A distal fibular fracture is extremely rare. Accurate diagnosis requires careful palpation of the proximal fibula and imaging of the entire lower leg. Favorable outcomes can be achieved through proper restoration of fibular length and stabilization of the ankle mortise. • This case represents the first report of a double Maisonneuve fracture in which the distal fibular injury followed a Weber type A configuration. • Accurate diagnosis required imaging of both the ankle and entire lower leg, as proximal fibular fractures can be easily missed. • Internal fixation using nitinol staples was effective for the distal fracture, avoiding interference with syndesmotic hardware. • Restoration of fibular length with a foot distractor and stabilization using a one-third tubular plate resulted in favorable clinical outcomes.
Source: Trauma Case Reports
Institution: Teikyo University
Language: English
Subfield: Epidemiology
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $1,190
OpenAlex ID: W7125236647