Synchrotron frequency measurements using bunch by bunch longitudinal feedback system in a storage-ring with higher harmonic cavity
Year: 2026
Type: conference-paper
Abstract: The upgraded Advanced Photon Source (APS) features a 1408 MHz superconducting Bunch Lengthening System (BLS) to improve beam lifetime and emittance. The main RF system is significantly affected by ambient 60 Hz-harmonics noise, complicating the measurement of synchrotron frequency under varying higher harmonic cavity conditions. To address this, using Dimtel iGp12 processor-based longitudinal feedback system we developed two methods to measure synchrotron frequency effectively. Our approach involves driving multi-bunch beam modes by considering a span for synchrotron frequency sideband and analyzing mode amplitude changes across the sweep frequency range. The "slow" method scans fixed drive frequencies within a range, recording the beam response at each frequency. The “fast” approach drives the beam with a broadband chirp signal and analyzes the resulting single mode spectrum data. Both methods are tested during beam studies. Synchrotron frequency changes are measured in two setups: First, adjusting BLS voltage manually while keeping beam current constant. Second, BLS voltage varying as a function of decaying beam current. This paper presents, details of the measurement procedure and results from the beam-based machine studies.
Source: JACOW
Authors: Kallakuri,Pavana, Emery,Louis, Cheng,Weixing
Language: English
Subfield: Aerospace Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
OpenAlex ID: W7126063092
FWCI:
Cites:
Cited by:
Related to: