Work

Evaluation of the Use of a Medium Cut‐Off Dialyser Theranova 400 for Severe Metaldehyde Intoxication in Three Dogs: Dialytic Clearance and Therapeutic Response

Year: 2026
Type: article
Abstract: OBJECTIVE: To describe the clinical utility and toxin removal kinetics of a commercially available medium cut-off (MCO) haemodialyser as emergent treatment of severe metaldehyde intoxication in three dogs. SERIES SUMMARY: Three dogs presented to the emergency department with severe acute neurological signs, including seizures and incoercible tremors following metaldehyde ingestion. Medical therapy, including gastric decontamination and intravenous lipid emulsion, was unsuccessful in improving the neurological condition in all three dogs. Haemodialysis (HD) with an MCO dialyser was performed as emergency treatment to control the clinical signs of intoxication. Resolution of neurological signs was achieved in all dogs within a 4-h HD session without adverse effects. Metaldehyde concentration was measured serially during each treatment. Drug extraction rate, clearance and mass elimination by the MCO dialyser were calculated. The dialytic clearance was 12.5 times higher than the measured intrinsic clearance. UNIQUE INFORMATION PROVIDED: This case series describes the clinical efficacy of an MCO dialyser in the treatment of severe metaldehyde intoxication in dogs and provides unique insights on the metaldehyde clearance kinetics through an MCO dialyser.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,880
OpenAlex ID: W7127998013
FWCI:
Cites: 15
Cited by:
Related to: