Work

Fast Single Pulse Resolved Laser Induced Breakdown Spectroscopy (spr-LIBS) for In-Line Monitoring of Complete Film Removal in Ni/NiCr Thin-Film Systems

Year: 2026
Type: article
Abstract: An in-line monitoring system for ultra-short pulsed (USP) laser ablation was developed and assessed to two-dimensionally map the complete removal of a thin film.This method enables single pulse resolved monitoring based on Laser Induced Breakdown Spectroscopy (LIBS) for pulse repetition rates of up to 4 MHz.The transition from one 1.5 µm thin layer to another during laser ablation was detected.The mapping with Energy-dispersive X-ray Spectroscopy and our method are in very good agreement.Furthermore, an enhancement of the signal contrast was achieved with GHz bursts.
Language: English
Subfield: Spectroscopy
Field: Chemistry
Open Access status: diamond
OpenAlex ID: W7128523021
FWCI: 1.121
Cites: 16
Cited by: 1