Patlak-PBNT: a simple population-based Patlak model to generate [68Ga]Ga-PSMA-11 Ki parametric images for shortened total-body PET scan
Year: 2026
Type: article
Abstract: The objective of this study is to generate reliable Ki parametric images from short-duration total-body PET scan for clinical applications using a simple population-based Patlak model. We proposed a population-based Patlak model named Patlak-PBNT, which incorporates a population-based “normalized time” (PBNT) into the traditional Patlak plot. This model does not require long-duration PET scans to obtain an image-derived input function (IDIF) of full measured kinetics, thereby generating reliable Ki images from short-duration total-body PET scans. We evaluated the effectiveness of Patlak-PBNT based on 60-minute full-dynamic total-body [68Ga]Ga-PSMA-11 PET data collected from 20 subjects PET scans. For comparison, the Ki images generated by the traditional Patlak plot (t* = 20 min post-injection) with measured IDIF was used as the gold standard. The differences between Patlak-PBNT-generated Ki images and the gold standard were evaluated at both the voxel and volume of interest (VOI) levels. Compared to the traditional Patlak, Patlak-PBNT effectively reduces PET scan duration while maintaining the quality of generated Ki images. For [68Ga]Ga-PSMA-11, Ki images generated by Patlak-PBNT using only 40 minute dynamic PET images (20–60 min post-injection) show negligible differences compared to those generated by traditional Patlak with the same 40 minute dynamic PET images and a 60 minute full-duration IDIF, with a normalized mean squared error (NMSE) of 0.01, a Pearson correlation coefficient (Pearson’s r) of 0.99, and a peak signal-to-noise ratio (PSNR) of 75.27 dB. It is important to note that Ki images generated by Patlak-PBNT, using only 20 minute dynamic PET images (40–60 min post-injection), exhibit a high correlation with the gold standard in predefined VOIs, achieving a coefficient of determination (R2) of 0.92. The proposed Patlak-PBNT model reduces the dependency on a complete input function, thereby avoiding the need for long-duration PET scans typically required to obtain a full input function. When utilizing dynamic PET images of identical scan durations (20–60 min post-injection), the Ki images generated by Patlak-PBNT and traditional Patlak are essentially identical. Furthermore, even when the scan duration is further reduced, the Patlak-PBNT method is capable of quantifying 20 minute dynamic [68Ga]Ga-PSMA-11 total-body PET images. Question Is there a method similar yet simpler than population-based input function (PBIF) for generating reliable Ki parametric images from short-duration total-body PET scans? Pertinent findings A linear population-based normalized time (PBNT) was proposed and integrated into the traditional Patlak model, forming a population-based Patlak model that enables the generation of reliable Ki parametric imaging from short-duration total-body PET scans. Implications for patient care Reliable Ki parametric images can be generated from short-duration PET scans, avoiding patient discomfort caused by longer PET scans.
Source: EJNMMI Physics
Authors: Lianghua Li, Wenjian Gu, Wentong Yang, Weijun Wei, Jianjun Liu, Gang Huang, Junbo Ge, Gongning Luo, Shiming Xu, Yun Zhou
Language: English
Subfield: Radiology, Nuclear Medicine and Imaging
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $2,490
OpenAlex ID: W7128926787