Abstract: Cold indoor environments in rural Andean housing raise concerns about thermal comfort, yet the applicability of existing comfort models to these contexts remains insufficiently examined. This study has compared predictions from five thermal comfort models, including PMV, aPMV, and regional approaches, against field data. Data were collected from 154 residents of Langui (3,969 m.a.s.l.) through culturally adapted surveys and environmental measurements. The aPMV model showed the highest agreement with thermal sensation votes, achieving 58.4% accuracy (±1 category), and enabled the definition of a comfort range between 14 °C and 25 °C. The results emphasize the need for local design criteria that address cold indoor conditions in Andean housing.
Source: Revista Hábitat Sustentable
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Keywords: thermal comfort models, PMV, thermal sensation
Open Access status: diamond