Work

Precision mass measurement of Zn 61 and updated F t value for conserved vector current tests

Year: 2026
Type: article
Abstract: We report a high-precision mass measurement of Zn 61 , performed with the ISOLTRAP mass spectrometer at ISOLDE, CERN. Our result agrees with a recent measurement from the LEBIT Penning trap at FRIB and reduces the mass uncertainty by a factor of four. Combined with recent measurements of the mirror nuclide Ga 61 performed by TITAN at TRIUMF and CSRe at HIRFL, we obtain a more accurate Q value. This new value slightly improves the determination of the corresponding F t value in the T z = 1 / 2 mirror beta decays used to test the conserved vector current hypothesis in the standard model.
Language: English
Open Access status: hybrid