Work

Isolating cells from zebrafish eyes with laser capture microdissection

Year: 2024
Type: dissertation
Abstract: The mouse has proven to be a great model in biomedical research. However, in eye research, mice show multiple limitations due to being nocturnal animals with poor eyesight. In addition, mice cannot see red light due to absence of red cone photoreceptors. Zebrafish, on the other hand, are diurnal species with high-acuity vision and excellent colour vision like humans. However, due to the small size of the eye, isolating cells for gene expression analysis remains a problem, as the samples isolated via conventional dissection methods are not reaching adequate purity. In order to solve this problem, other cell isolation methods, such as laser capture microdissection (LCM), have been considered to be used instead. This thesis focused on characterising the molecular signature of the zebrafish RPE. In order to do so, the potential of a conventional dissection method and the LCM technique as cell isolation methods was evaluated. The conventional dissection method involved the removal of the cornea, lens, and vitreous from the eye with a scalpel and forceps, followed by the detachment of the retina and ultimately the isolation of retinal pigment epithelium (RPE) cells from the choroid with a hyaluronidase mix. The ArcturusXT LCM system was used to isolate zebrafish RPE, outer nuclear layer (ONL), and choroid. Furthermore, the area where the RPE microvilli and photoreceptor outer segment (POS) overlap was isolated to determine whether it had sufficient quantity and quality of messenger ribonucleic acid (mRNA). The specimens used in this study were 14–18-month-old zebrafish whose eyes were dissected with a cryostat into thin 8–20 μm sections and mounted on PEN membrane glass slides prior to the LCM. The LCM isolates were collected with CapSure™ Macro LCM Caps, from which the mRNA was extracted using the RNeasy Micro Kit. The quantity of the extracted mRNA was measured with a spectrophotometer, and the quality was assessed with a fragment analyser. Reverse transcription polymerase chain reaction (RT-PCR) analysis was performed on conventionally dissected samples to evaluate the purity of the samples. In addition, RT-PCR analysis was performed for 20 potential zebrafish RPE genes to study their expression in the zebrafish RPE. The conventional dissection technique was found to be insufficient for producing zebrafish RPE and retinal samples of adequate purity. Cells were isolated from 8 zebrafish eyes with the LCM technique for two mRNA samples: ONL and RPE microvilli-photoreceptor outer segment (POS). The quality and quantity of the extracted mRNA in the ONL sample were sufficient for potential downstream analysis. The area of the RPE microvilli-POS, on the other hand, was found to have inadequate mRNA quality and yield to confound the purity of the RPE or the ONL samples. The zebrafish RPE obtained by conventional dissection was shown to express all genes of interest; however, their expression is difficult to confirm as the only available samples were cross-contaminated according to previous RT-PCR analysis. In conclusion, the LCM technique shows great promise for isolating zebrafish ONL. However, due to the small number of samples, the reproducibility of the results cannot be guaranteed. Because of this, the analysis must be repeated with other zebrafish ONL samples, as well as with the zebrafish RPE and choroid. This will be done as part of the following study.
Language: English
Subfield: Ophthalmology
Field: Medicine
Open Access status: green
OpenAlex ID: W7132953613
Cites: 80
Cited by:
Related to: 10