Work

Byggnader för reservtjänster : Introduktion till byggnader som batterier för reservtjänster på den svenska elmarknaden

Year: 2025
Type: dissertation
Abstract: Sweden’s future electricity demand is expected to increase primarily due to large-scale electrification, particularly in the transport and industrial sectors, rather than population growth. This in turn drives rapid integration of new energy sources into the grid. This might lead to capacity congestion and requires an increase in transmission capacity. However, given the long duration required for expansion, the system will face periods of congestion, resulting in heightened reliability challenges. In this context, maintaining balance between supply and demand all the times is essential to ensure stable grid operation. Since buildings are considered as ubiquitous energy consumers, optimizing their operation can help bridge the emerging energy gaps in the grid balance. This thesis investigates how buildings can be utilized as flexible thermal energy storage by shifting electric heating to provide reserve services and reduce demand by peak shifting while maintaining occupant comfort. The study models a multi-storey building following Swedish building rules (Boverket Byggregler, BRR), in Sweden’s SE3 price-area. The building is modeled as a reduced 1 Resistor 1 Capacitor (1R1C) thermal model, and is evaluated through three scheduling cases using YALMIP in MATLAB: (1) passive demand side management (DSM) via optimized heating, ventilation, and air conditioning (HVAC) schedule; (2) DSM with an external storage tank, co scheduled with HVAC operation; and (3) DSM with storage co-optimized to participate in a capacity market. The first two cases are solved using a deterministic optimization framework while the third case uses a two-stage stochastic optimization framework equipped with a risk aversion strategy called Target- Conditional Value-at-Risk (TCVaR). With T-CVaR the unfortunate risks or discrepancies in scheduling are mitigated. The case 1 successfully shifts peak loads and reduces the operating costs, revealing room for further gains via external energy storage system. The case 2, which integrated external thermal storage although modest achieved slight cost reduction compared to the previous case, while maintaining energy usage. When multiple buildings are aggregated and coordinated to participate in ancillary service like manual-Frequency Restoration Reserve (mFRR) comfort constraints are satisfied. This demonstrates that well coordinated cluster of buildings can offer grid flexibility without compromising the indoor comfort. Overall these findings indicate that optimizing building energy usage especially with an external storage can reduce costs and enables to act as a flexibility without compromising the occupant comfort.
Language: English
Open Access status: green
OpenAlex ID: W7135902074
Cites: 26
Cited by:
Related to: 10