Combined Image Synthesis and Deformable Registration Framework for MRI-Based Adaptive Radiotherapy
Year: 2025
Type: dissertation
Abstract: Head and neck cancer (HNC) is among the most challenging malignancies to treat with ra-diotherapy due to its heterogeneous anatomy and the close proximity of tumors to organs at risk (OARs). Adaptive radiotherapy (ART) has emerged to address day-to-day anatom-ical changes during treatment by adjusting the plan to the patient's current anatomy, with the goals of improving dose accuracy, reducing treatment-related toxicity, and maintaining effective tumor control. In this workflow, magnetic resonance imaging (MRI) provides supe-rior soft-tissue contrast without ionizing radiation, enabling better diagnosis and treatment planning; computed tomography (CT) remains indispensable for dose calculation; and cone-beam CT (CBCT), acquired before each fraction, offers daily volumetric imaging to monitor anatomy and align the pCT and its dose plan to the day's anatomy. However, CBCT suffers from noise, artifacts, and inconsistent Hounsfield Units (HU), which limit direct dose calcu-lation. A fully MRI-based ART pathway could reduce reliance on pCT, but this requires (i) reliable MRI-to-CT synthesis to supply CT-equivalent information for dose calculation and (ii) accurate deformable registration to align the synthetic CT (sCT) with the daily CBCT. This thesis proposes a two-stage deep learning pipeline for MRI-to-CBCT deformable regis-tration. In the first stage, multiple synthesis networks were investigated, including a baseline Conditional Generative Adversarial Network (CGAN), a Feature-Consistency CGAN (FC-GAN) incorporating a feature consistency loss term, and a transformer-based MRI-to-CT Improved Denoising Diffusion Probabilistic Model (MC-IDDPM) for synthesizing CT from MRI. The goal is to generate sCTs with sufficient anatomical and intensity fidelity to be suitable for subsequent tasks such as dose calculation, segmentation, and deformable regis-tration, which are essential in treatment planning and delivery. In the second deformable registration stage, the objective was to align the planning CT (pCT) or the sCT to the daily CBCTs, achieving fine spatial alignment, particularly within the tumor and OAR regions. Synthesis was evaluated on both the SynthRad2023 brain dataset [1] and an institutional HNC cohort comprising 338 patients with paired MRI, CT, and serial CBCTs, while regis-tration was assessed exclusively on the HNC dataset, where all three modalities were avail-able. On HNC cohort, FCGAN enhanced structural fidelity over the baseline CGAN with an 29.0% Mean Absolute Error (MAE) reduction and respective increases in Pearson Cor-relation Coefficient (PCC), Peak Signal to Noise Ratio (PSNR), and Structural Similarity Index Measure (SSIM) of 0.6%, 7.4%, and 1.1%. MC-IDDPM reduced MAE by 22.7% and increased PCC and PSNR by 0.3% and 8.1%, respectively, compared with FCGAN, demonstrating improved structural accuracy. Compared with FCGAN, MC-IDDPM yields a 1.2%higher Dice for the skull, but is lower by 1.5% for the spinal cord and by 5.4% for each parotid (left and right). Relative to CGAN, FCGAN raises the Dice by 6.5% for the spinal cord, 1.2% for the skull, and 5.7% for each parotid gland. In summary, FCGAN performs better on soft tissues (spinal cord and parotids), whereas MC-IDDPM is superior for bony anatomy. With test-time augmentation, MC-IDDPM achieved 1.3% reduction in dose MAE and dose–volume histogram (DVH) difference relative to FCGAN, reflecting enhanced dosi-metric consistency. MC-IDDPM also outperformed FCGAN and CGAN across all image similarity metrics, including MAE, PCC, PSNR, and SSIM, on the SynthRad2023 brain dataset.
Author: Sargordi, Shima
Institution: Polytechnique Montréal
Language: English
Subfield: Radiation
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: green
Funder: Mitacs
OpenAlex ID: W7140354590