Work

原子間力顕微鏡による熱電対中の異常ネルンスト信号の高分解能マッピング

Year: 2025
Type: dissertation
Abstract: High-resolution mapping of anomalous Nernst signals in Thermopiles through Atomic Force Microscopy. 「原子間力顕微鏡による熱電対中の異常ネルンスト信号の高分解能マッピング」 ULLERITHODI Manaal Resivi StudentID# 47-236101 Otani Laboratory Yoshichika Otani Keywords: anomalous Nernst effect, Thermoelectric imaging, Atomic Force Microscopy, Thermopile Introduction The anomalous Nernst effect (ANE), which involves the generation of a transverse electric field in response to a longitudinal temperature gradient in magnetic materials, has recently attracted considerable interest in the field of spin-caloritronics [1-2]. Thermoelectric devices that exploit this phenomenon, hereafter referred to as anomalous Nernst thermopiles (ANTs), are being actively investigated for their potential in efficient thermal-to-electrical energy conversion. Their applications range from waste heat recovery and on-chip power generation to solid-state cooling. Despite the growing attention on ANTs, most previous studies have been limited to macroscopic voltage measurements, providing little insight into the microscale thermoelectric and magnetic behavior that governs device performance[3-5]. To advance the understanding and optimization of these devices, it is crucial to develop experimental methods that can probe internal thermoelectric and magnetic phenomena at the microscale. In this context, a magnetic imaging technique based on the ANE and implemented using atomic force microscopy (AFM) was developed [6]. In the present study, this technique has been further refined by adopting a vertical device structure, which enhances the applied temperature gradient and improves the signal-to-noise ratio (SNR) in the imaging process. Utilizing this improved approach, we successfully achieved spatially-resolved mapping of the magnetic response within a Nernst thermopile, providing new insights into its internal operation and paving the way for the rational design of more efficient thermoelectric devices. Permalloy (Ni81Fe19) and Iron (Fe) are well-studied ferromagnets that have opposing transverse Seebeck coefficients. This study aims to map the thermoelectric response within an ANT fabricated using these simple materials. Although these materials produce a weak Nernst signal, they would be a good starting point to demonstrate the benefits of this technique. Experimental In this study, contact-mode AFM was employed to resolve the ANE in a thermopile structure spatially. During scanning, the AFM tip, maintained at ambient temperature, makes physical contact with the sample surface, which is locally heated from below. This configuration creates
Language: English
Open Access status: green
OpenAlex ID: W7144468128
Cites: 34
Cited by:
Related to: 10