Abstract: This research paper aims to present the Comparative Study of Spectrogram, Cepstrum and Mel-Frequency Analysis for Bushing Fault Diagnosis using Sound Signal, have three case of condition testing for shaded pole motor. This research used shaded pole motor from Table Fan to testing. The Spectrogram were detected for bushing of shaded pole motor are healthy, but this method difficult to separate normal and crack on bushing because can be distracted by ambient noise, Cepstrum confirmed that the faulted on bushing and easy than Spectrogram to separate normal and crack on bushing because can be reduce ambient noise and Mel Frequency Analysis confirmed that the faulted on bushing and easy than Spectrogram to separate normal and crack on bushing of shaded pole motor with a slightly damaged front sliding bushing. The spectrogram, Cepstrum and Mel Frequency Analysis confirmed that the sound signal effects changed.