Work

高速炉冷却系配管における流れの剥離現象に関する基礎研究; 高レイノルズ数領域におけるマルチエルボ内複雑流動構造の解明(先行基礎工学研究に関する平成19年度共同研究報告書)

Year: 2009
Type: report
Abstract: At Tohoku University, 1/15 scale and 1/7 scale flow tests are being performed in order to clarify an unsteady flow structure in the cold leg piping and to investigate the scale effect. In FY2007, the 1/15 scale test was carried out using a double elbow geometry. It was confirmed that there existed a separation along the inner wall of the 1st elbow and a large swirling flow in the 2nd elbow. Furthermore, the unsteady flow formed in and/or behind the separation region was transported downstream and flows into the center area of the 2nd elbow. At JAEA, a numerical analytical evaluation method is being developed to evaluate the feasibility of the reactor design. In FY2007, numerical analyses for the 1/15 scale test were performed using the commercial thermal-hydraulics code FLUENT. The analyses showed that the trend of calculated velocity distributions was in good agreement with the visualization test results.
Language: Japanese
Field: Energy
Open Access status: green
OpenAlex ID: W389567883
Cites:
Cited by:
Related to: 10