Sonazoid Contrast-Enhanced Ultrasound Hypoenhancement Characteristics and Influencing Factors of Hepatic Hemangiomas: A Multicenter Study
Year: 2026
Type: article
Study design: Observational Study
Abstract: OBJECTIVE: Given the high hypoenhancement prevalence of hepatic hemangiomas (HHs) during the transitional phase and Kupffer phase (KP) of Sonazoid contrast-enhanced ultrasound (CEUS), this study aimed to investigate the hypoenhancement phenomenon pattern and its influencing factors. METHODS: This was a prospective multicenter study. A total of 136 patients with HHs were enrolled from 26 medical centers, including 76 cases in the KP hypoenhancement group and 60 cases in the KP non-hypoenhancement group. Enhancement characteristics and patterns at different time points during the transitional phase were analyzed between the two groups. Statistical analyses included Mann-Whitney U test for two independent samples, chi-square test or Fisher's exact test for categorical variables and Spearman's rank correlation analysis for the relationship between hypoenhancement prevalence and time points. Survival analysis was used to compare differences in the start time of hypoenhancement among HHs with different characteristics. Multivariate Cox regression analysis was performed to identify the influencing factors of KP hypoenhancement. RESULTS: = 0.993, p < 0.001). The main start time of hypoenhancement was 4 min (p < 0.001). The median hypoenhancement time in the KP hypoenhancement group was 5.5 min. Two-dimensional ultrasound (2-D-US) echo type and maximum diameter were independent influencing factors for Sonazoid KP hypoenhancement: hypoechoic lesions were more likely to present hypoenhancement compared with hyperechoic ones (HR = 1.80, 95% CI: 1.10-2.95, p = 0.020); both lesions ≥5 cm and those between 2 and 5 cm had a higher likelihood of hypoenhancement compared with lesions <2 cm, with HR = 2.58 (95% CI: 1.18-5.65, p = 0.018) and HR = 2.32 (95% CI: 1.35-3.97, p = 0.002), respectively. CONCLUSION: More than half of HHs show hypoenhancement in the KP of Sonazoid CEUS, and mild hypoenhancement is the main enhancement pattern among hypoenhancement cases. Hypoenhancement mostly occurs after 4 min, and the hypoenhancement prevalence gradually increases over time. The independent influencing factor for KP hypoenhancement is 2-D-US hypoechogenicity and maximum diameter greater than 2 cm.
Source: Ultrasound in Medicine & Biology
Authors: Yunhao Luo, Danlin Wen, Jiakai Liu, Jing Zhang, Zhengrong Song, Xiaomin Shu, Xin Luo, Yang Liu, Yan Liu, Wei Li, Qiang Mao, Yunquan Zhou, Liwen Ma, Li Li, Yaping Zhang, Shiping Wu, Yi Hu, Yuanlin Gou, Yanling Fu, Xiuli He, Lei Yang, Xueli Peng, Keji Li, Jian Liu, Yang Zhou, Lang Qiao
Institutions: Sichuan Integrative Medicine Hosipital, Chengdu University of Traditional Chinese Medicine, Chengdu Medical College, First Affiliated Hospital of Chengdu Medical College, Mianyang Third People's Hospital, Panzhihua University, Second People’s Hospital of Yibin, Third People's Hospital of Chengdu, Chengdu Fifth People's Hospital, Southwest Jiaotong University, The First People's Hospital of Neijiang, Affiliated Hospital of North Sichuan Medical College, Panzhihua Central Hospital
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $2,650
Award: G7587746792
OpenAlex ID: W7148488945
