Evolution of Ablation: Continuous Technological Improvements and Procedural Standardization
Year: 2026
Type: article
Abstract: Luigi Solbiati, MD, FCIRSE It has now been 41 years since the first percutaneous “treatment without removal” worldwide of solid tumor (ethanol injection of parathyroid adenoma) was reported[ 1 ] and 40 years since the first alcohol ablation of hepatocellular carcinoma was performed,[ 2 ] and nowadays image-guided ablation of benign and malignant lesions of many organs via percutaneous, laparoscopic, or intraoperative approaches has widely spread throughout the world. Over the years, there has been (and it goes on still today) an impressive development of guidance techniques and energy sources aimed at achieving high treatment efficacy for lesions located in increasingly complex and challenging sites, and in a growing number of organs. Among guidance modalities, in addition to the “historical” ultrasound (US) and computed tomography (CT), over the past 10 years, there has been progressive development of robotic technologies and augmented reality (AR) systems. Robotic guidance systems differ from one another in terms of structure (stand-alone, floor-mounted, etc.), diagnostic modality of guidance (CT, cone-beam CT, fluoro-CT), tracking system (electromagnetic with fiducials or infrared optical with infrared sensors), and number of degrees of freedom. All robotic systems are equipped with single- or multiplanar/multiprobe planning and placement capabilities, and allow either manual or automated needle insertion, real-time monitoring and adjustment for patient respiration and/or needle deviation, and are provided with posttreatment ablation confirmation software. It has been demonstrated that robotic systems achieve a significantly shorter needle tip-to-target distance and a markedly lower needle-tip deviation compared with freehand techniques, as well as improved accuracy—particularly when multiple needle placement (stereotaxy) is required or when small targets in challenging locations must be reached. In addition, they allow for reduced radiation exposure compared with CT-guided procedures. Notably, robotic systems considerably reduce the outcome variability between novice and experienced operators, thereby enabling greater standardization and reproducibility of interventional procedures (the so-called “democratization”).[ 3 ] The main disadvantages of these systems are the potential increase in procedural time and the higher costs, which make their use more advisable in high-volume centers. Another innovative guidance method is AR, which can be used either as a stand-alone technique or in combination with US and CT. In AR, real and virtual are intertwined; real-world and digital objects interact and can be manipulated simultaneously. AR systems may be based on optical technology or, with better results, on infrared technology. The combined images can be displayed on smartglasses, as well as on smartphones, tablets, or monitors. The advantages of AR, well perceived by junior staff members, include accurate planning in three dimensions (3D), increased speed, decreased needle manipulation, significant reduction of radiation burden (CT scans) to patients, and, as for robotic systems, usability for every organ, with any ablation device, and both in US and CT rooms.[ 4 ] A new and highly promising system of AR guidance has recently been proposed, consisting of a dual camera and a CT-mounted AR navigation system without fiducial markers, electromagnetic tracking, or head-mounted displays. The two cameras rigidly attached to the CT gantry provide real-time axial and sagittal views, onto which anatomy and segmented targets from recent CT acquisition are overlaid. By directly registering the cameras to the CT coordinate system, the need for repeat calibration is eliminated, and seamless integration into the standard CT-guided workflow is achieved.[ 5 ] Regarding ablative techniques, radiofrequency ablation seemed in recent years to be destined for a marked decline, but the recent introduction of radiofrequency technologies capable of delivering significantly higher power (up to 370W), combined with additional favorable features (optimized algorithm for each organ, two-piece cooled electrodes, transient acoustic return when impedance increases, etc.) has once again positioned this technique as a valid alternative to microwave ablation and cryoablation, allowing to achieve large ablation volumes and safe ablations also close to critical structures through extremely precise temperature control always below 100°C.[ 6 ] “Combined” techniques are also proving increasingly useful, particularly in liver malignancies, such as the association of thermal ablation with chemoembolization (TACE) after occlusion of afferent vessels (balloon-assisted thermal ablation associated with DEB-TACE, so-called “thermal segmentectomy”) as well as the association of thermal ablation and radioembolization. A large amount of Y 90 can be administered in a single dose to treat liver malignancies localized to one or two adjacent segments, too large, or in an unsafe location for other local treatments, allowing to spare the surrounding normal liver and reducing the risk of liver failure (“radiation segmentectomy”). Among the applications of ablation for lesions of superficial organs, thyroid ablation with radiofrequency (or, less commonly, with microwaves or laser) has experienced the greatest increase of all ablation fields over the past 5 to 10 years, to such an extent that surgery for benign thyroid nodules and small papillary thyroid carcinomas is expected to decline dramatically in the near future. US and contrast-enhanced US are the imaging modalities of choice both for performing the procedure and for the final assessment of the ablation outcome. For small breast carcinomas, cryoablation is progressively establishing itself as the most important ablative modality capable of replacing surgery in some instances, thanks to its favorable characteristics (precision, minimal invasiveness, clear definition of necrotic volumes, and optimal control of thermal diffusion toward the skin planes). In addition, cryoablation may act as an in situ tumor vaccine in breast cancer, and when combined with immunotherapy, it synergistically enhances systemic antitumor immunity and clinical response. A new ablative modality is histotripsy, a nonthermal, nonionizing, and noninvasive therapy consisting of short, high-amplitude micro-pulses of US that generate cavitation at the focal point, collapse, and sub-cellular destruction of targeted tissue. Its major advantages compared with all the other ablative modalities are the clear-cut demarcation of treated versus untreated tumor and the “resistance” to histotripsy of collagen-based structures, such as bile ducts, urothelium, and blood vessel walls. This makes histotripsy particularly suitable for the treatment of lesions adjacent to these collagen-rich structures.[ 7 ] In addition, histotripsy ablation triggers a profound local inflammatory reaction that can initiate a systemic antitumor immune response with the release of tumor-associated antigens and an increase of dendritic cells and CD8+ cytotoxic T lymphocytes (the so-called “abscopal effect”) that may enhance cancer immunotherapy, leading to a favorable response also for additional, nondirectly ablated lesions.[ 8 ] The use of Y 90 microspheres combined with a biocompatible “bioglue” for direct percutaneous intratumoral injection under US or CT guidance is currently under investigation following a long preliminary experimental phase. This relatively simple and rapid technique, theoretically applicable to most organs and lesions, but requiring extremely precise guidance due to the very rapid polymerization of the injected material, could achieve widespread adoption in the near future. The numerous impressive technological developments in ablation that have occurred over the years have made it possible to significantly improve the quality of all the phases of ablation; however, the final success depends not only on the materials and techniques used, but also on the skill of the operators throughout the whole procedure. Consequently, the ultimate goal is to make ablation standardized and reproducible, reducing as much as possible the wide variability in results among different centers. High rates of technical success are often reported, but are sometimes followed by disappointing local progression rates. Standardization must be achieved over time, mostly in the phases of pre-ablation and post-ablation assessment. In the pre-ablation phase, standardization must mandatorily be achieved through the multidisciplinary evaluation of each individual lesion to be treated. The direct participation also of interventional oncologists in the multidisciplinary team has been reported to markedly increase the number of patients referred for ablation and the number of patients receiving curative treatment. Whenever possible, multidisciplinary evaluation should be based on existing guidelines or consensus statements, which are now available for numerous types of neoplasms. The key element in the standardization process, however, is the confirmation of the volume of necrosis obtained. It is now clearly established that, in the treatment of neoplastic diseases of abdominal organs, an ablative margin of at least 5 mm—and ideally 10 mm—achieved circumferentially (360°) around the target in 3D, is essential to correctly declare technical success and to reasonably expect optimal long-term local tumor control. For many years, surgeons have rightly pointed out that the main difference between surgery and ablation lies in the method used to evaluate outcomes. While surgical results benefit from precise histological assessment performed by pathologists after every operation, evaluation of ablation outcomes has so far relied on side-by-side visual inspection of pre- and posttreatment CT scans, often performed by the same interventional oncologist who performed the procedure. This approach should no longer be considered acceptable, having been demonstrated to have a high level of failure and, in addition, without any difference between experienced and nonexperienced radiologists.[ 9 ] The solution to this problem lies in the systematic use, after every ablative treatment in every organ, of dedicated ablation confirmation software, which is now widely available on the market.[ 10 ] Ablation confirmation software can be integrated either in CT machines or in stereotactic/robotic systems, or in ablation machines or be stand-alone, can use either rigid registration or, preferably, deformable registration, automatic or semi-automatic segmentation, and should be capable of registering all the follow-up CT scans, but the most important feature is that every ablation confirmation software must be able to perform automatic quantitative assessment of the predefined minimal ablative margin (MAM).[ 10 ] MAM should be considered a quantitative imaging biomarker and treated with the same scientific rigor as drugs, and possibly be integrated into reimbursement or quality assurance.[ 11 ] Clearly, if the interventional procedure is performed in a CT room or a CT angio-suite, with or without the use of US and/or image fusion, software-based evaluation can be performed immediately at the end of the ablation. If a complete and sufficient 3D ablative margin is not demonstrated, the ablation can be completed during the same session, with evident advantages for both patients and operators. A significant example of standardization has recently been proposed by Odisio et al[ 10 ] and Paolucci et al[ 12 ] for colorectal liver metastases ablation. In conclusion, even if the costs associated with more complex technology, time prolongation, etc., can limit the widespread adoption of standardized protocols for ablation, every effort must be made to increase the efficacy and consequently the credibility of thermal ablation. In this scenario, the standardization will represent a great step forward. Publication History Article published online: 06 April 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Pvt. Ltd. A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
Author: Luigi Solbiati
Institution: IRCCS Humanitas Research Hospital
Language: English
Subfield: Hepatology
Field: Medicine
Domain: Health Sciences
Open Access status: diamond
OpenAlex ID: W7151069221