Work

Radiological assessment of navigated pedicle screw placement in the cervical spine: a comparative evaluation of a novel orthogonal view evaluation method (ovem) versus other classification systems (Neo/Modified Gertzbein-Robbins/Wiesner)

Year: 2026
Type: article
Study design: Observational Study
Abstract: STUDY DESIGN: A retrospective, comparison study. PURPOSE: This study compares different computed tomography (CT)-based methods for evaluating the postoperative position of cervical pedicle screws (CPS). Specifically, our novel Orthogonal View Evaluation Method (OVEM) alongside the Neo, modified Gerzbein-Robbins, and Wiesner classifications to validate a standardized system for postoperative assessment of screw placement in the cervical spine. METHODS: All enrolled patients underwent navigated, posterior stabilization using CPS in the subaxial spine (C3-C6). The intra- and inter-observer assessment was carried out using two statistical methods: the Fleiss Kappa and the Gwet´s agreement coefficient (Gwet´s AC1). RESULTS: A total of 90 (60 men and 30 women) patients with total number of screws 275 (median 2, IQR 2 to 4) were enrolled in the study. The OVEM classification demonstrated a statistically significant lower number of screws categorized as correctly placed compared to the other classification across all reviewers (p < 0.001). The reliability analysis showed the highest agreement for OVEM 2 and Neo 2 for Reviewer 1, with Gwet's AC1 (95% CI) of 0.83 (0.77, 0.888) and OVEM for Reviewers 2 and 3 with Gwet's AC1 (95% CI) of 0.87 (0.818, 0.917). Intra-observer agreement was highest for Reviewer 1 in OVEM 2 with Gwet's AC1 (95% CI) of 0.97 (0.943, 1.0), for Reviewer 2 in Neo with 0.97 (0.941, 1.0), and for Reviewer 3 in OVEM with 0.90 (0.829, 0.970). Inter-observer agreement was highest for Neo, with Gwet's AC1 (95% CI) of 0.89 (0.855, 0.927) among Reviewers 1, 2, and 3. CONCLUSIONS: OVEM evaluation method appears to be more sensitive to detect misplaced screws, has similar reliability and reproducibility in comparison to Neo/modified Gerzbein-Robbins/Wiesner classifications.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: hybrid
Estimated APC paid: $2,790
OpenAlex ID: W7155179147
FWCI:
Cites: 26
Cited by:
Related to: 10