Combined Bentall, Coronary Artery Bypass Grafting and Implantation of Ascyrus Medical Dissection Stent Landed Inside a Thoracic Endovascular Aortic Repair Stent
Year: 2026
Type: article
Study design: Case Report
Abstract: A 58-year-old male presented with Acute Type A Aortic Dissection (ATAAD) and left lower limb paralysis with a history of previously implanted Thoracic Endovascular Aortic Repair (TEVAR). Entry tear of the ATAAD was evident within the ascending aorta with extension to distal left main and supra-aortic branches creating a dissection flap over the proximal end of the TEVAR stent causing a stent lumen blockage. Patient underwent emergency surgical repair with Bentall procedure and deployment of small Ascyrus Medical Dissection Stent (AMDS) landed distally inside the TEVAR stent and coronary artery bypass grafting (CABG), all with good effect. The patient did not have any clinical or biochemical organ malperfusion at 30-day follow-up. AMDS placement inside a TEVAR stent can clinically be an effective strategy for management of post ATAAD malperfusion with complex extensive disease requiring concurrent surgical fixations.
Source: Journal of Clinical Medicine
DOI: 10.3390/jcm15093329
Authors: Robert Grant, Pouya Nezafati, Bruce French
Institutions: John Hunter Hospital, Liverpool Hospital
Language: English
Subfield: Pulmonary and Respiratory Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W7156728401
FWCI:
Cites:
Cited by:
Related to:
