Safe Percutaneous Dilatational Tracheostomy Using a Pre‐Measured Light‐Guided Endotracheal Tube Withdrawal Technique: A Case Report
Year: 2026
Type: article
Study design: Case Report
Abstract: Percutaneous dilatational tracheostomy (PDT) is a bedside procedure for patients requiring prolonged mechanical ventilation. Although its overall safety is comparable to that of surgical tracheostomy, complications related to endotracheal tube (ETT) manipulation remain a concern. In this report, we describe a simple, reproducible two-step approach for ETT repositioning during PDT that (1) pre-measures an individualized withdrawal distance using bronchoscopic illumination and (2) confirms final positioning in real time by transillumination at the incision site in a patient requiring tracheostomy after prolonged mechanical ventilation. The procedure was completed within 20 min without complications. This technique may facilitate safer ETT repositioning during PDT.
Source: Respirology Case Reports
DOI: 10.1002/rcr2.70637
Authors: Yuya Aoki, Masaki Kono, Takuo Yoshida
Language: English
Subfield: Pulmonary and Respiratory Medicine