Disturbance-Observer-Based Fault-Tolerant Sensorless Speed Control for Three-Phase Induction Motors

Year: 2026
Type: article
Abstract: Speed sensorless control in three-phase induction motors relies on accurate observer‑based speed estimation, making it susceptible to current sensor faults. Thus, incorporating an FTC mechanism is crucial to maintain robustness and reliability under fault conditions. This study contributes to provides a significant advancement in the development of resilient control systems for electric drives, addressing critical challenges in maintaining performance under fault conditions. This study develop a FTC strategy integrated with sensorless speed control for an induction motor hardware platform. A disturbance observer (DO) approach is employed to simultaneously estimate both rotational speed and disturbance signals, enabling the distinction between current sensor faults and load torque variations. Experimental-based evaluations were performed using integration between MATLAB/Simulink and hardware. The performance of the proposed algorithm was evaluated through three tests: the Set‑Point Change Test, the Torque‑Load Variation Test, and the Current‑Sensor Fault Test. Compared with a baseline DO-based sensorless controller without FTC, the proposed method prevents fault-induced degradation (e.g., loss of steady-state tracking/hunting behavior) by reconstructing the corrupted current channel and maintaining stable closed-loop operation during the fault. Under a step bias fault, the proposed scheme achieves a current recovery time of approximately 1.56 s, after which the speed response returns to the steady-state tracking band without current surge. The results demonstrate that the proposed method effectively compensates current-sensor faults in measurable terms thereby improving the robustness and reliability of DO-based sensorless induction-motor drives.
Language: English
Open Access status: diamond
OpenAlex ID: W7164413183
FWCI: 1.316
Cites:
Cited by: 1
Related to: 10