Initiation of Stress Corrosion Cracking in Brass Components for Drinking Water Systems: Selected Case Studies
Year: 2026
Type: article
Abstract: Failure of various components in internal drinking water systems leads to water leakage and high economic costs. Brass is a promising material for machining such components; however, it is sensitive to special forms of corrosion. Dezincification of duplex (α+β') brass can cause dealloying and cracking of components and also lead to the release of lead into drinking water, which is one of the greatest health concerns in these systems. In the present study, the microstructure and fractures of three brass components that cracked a short or moderate time after the start of operation were investigated. The investigation showed their sensitivity to cracking regardless of the presence of a corrosive environment.
Source: Materiali in tehnologije
Authors: Mirjam Bajt Leban, Tadeja Kosec
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold