A Unified Power Calculation Scheme for Single-Phase Droop-Based Inverters Considering the Use of Nonlinear Loads

Year: 2026
Type: article
Abstract: The dynamic performance of droop-controlled single-phase voltage-source inverters (VSIs) strongly depends on the accurate and fast calculation of active (P) and reactive (Q) powers under nonlinear load (NLL) conditions. Existing PQ calculation methods have been developed independently, most using a second-order generalized integrator (SOGI) approach, masking their structural relationships. This paper introduces a unified framework that interprets these PQ calculation approaches as combinations of input filters, intermediate notch filters, and output low-pass filters, enabling a clear spectral-domain analysis. Using this framework, the paper reveals that the current-side orthogonal filter in the fastest previously reported method (PQ4) causes a reactive power undershoot during load transients due to insufficient filtering. To overcome this limitation, a novel scheme (PQ2m) relocates the orthogonal filter to the voltage side and adds current-side SOGI filtering for improved distortion rejection. Analytical dynamic modeling enables a systematic design procedure, achieving an overshoot-free, dominant second-order response. Furthermore, incorporating notch filters (NFs) yields the PQ2mn variant and alternative PQ2mnb and PQ2mnc designs, which significantly suppress the output ripple while further accelerating the response speed. Hardware-in-the-Loop (HIL) results confirm settling-time reductions of up to 92.9% (PQ2m/PQ2mn), 95.75% (PQ2mnb), and 96.9% (PQ2mnc) compared to the conventional PQ1 method. Among all configurations, PQ2mn provides the best overall trade-off between dynamic enhancement and computational complexity.
Source: Energies
Language: English
Open Access status: gold
Estimated APC paid: $3,137
OpenAlex ID: W7168121609
FWCI:
Cites:
Cited by:
Related to: 10