Work

Analysis of volatile organic compounds from food contact materials: paperboard and fluoropolymer-coatings

Year: 2025
Type: dissertation
Abstract: Paper and board are used for packaging of moist as well as dry food and might therefore be exposed to a variety of relative humidity (rH) levels. For testing the transfer of off-flavours (taint) from packaging to food via gas phase (DIN EN 1230-2), rH has to be adjusted to 53 % or 75 %. In contrast, rH is neither taken into account when testing the odour (DIN EN 1230-1), nor in chemical migration of volatile organic substances (VOC) onto the adsorbent Tenax® (DIN EN 14338). The aim was to investigate the influence of relative humidity on the migration of VOC from recycled paper to Tenax® and the sensory profile of this material. Raising humidity caused an increase in the odour intensity as well as a change in the odour profile in human sensory tests. Likewise, gas chromatography-mass spectrometry (GC-MS) peak areas increased exponentially with humidity along with the number of detected substances. The strongest effect was observed at 75 and 100 % rH. Polar substances were more influenced by increasing humidity than less polar substances. The odour profile of the paper at 33 and 58% rH was described as cardboard-like, sweet and smoky. Impact substances for these olfactory impressions were (E)-2-nonenal, vanillin and 2-methoxyphenol as identified by GC-olfactometry (GC-O) and GC-MS. The increase of rH to 75 and 100 % resulted in the additional perception of cheesy/sweaty and fatty/rancid impressions, mainly caused by short-chain fatty acids and di-unsaturated aldehydes. Based on these results, rH has a strong effect on the desorption of VOC from paper and thus should be set to a defined level when testing the odour and the migration from paper and board according to DIN EN 1230-1 and DIN EN 14338, respectively. Fluoropolymer-coatings for kitchenware, like baking trays and frying pans, are made of polymeric per- and polyfluoroalkyl substances (PFAS) like polytetrafluoroethylene (PTFE), which is also known under the trade name Teflon. Non-polymeric PFAS are used as production aids in the fabrication of fluoropolymers. Growing concerns related to the impact of PFAS on the environment and the human health lead to an increasing interest in monitoring PFAS levels in food contact materials (FCMs) as well as their migration into food. The aim was to determine PFAS from fluoropolymer-based cookware coatings after thermal extraction by thermal desorption (TD)-GC-MS. MS measurements was performed using electron impact ionisation (EI) as well as positive and negative chemical ionisation (PCI and NCI). Injecting perfluorocarboxylic acids (PFCAs) and per- and polyfluoroethercarboxylic acids (PFECAs) into TD-GC-MS resulted in the detection of thermal degradation products: perfluoroalkenes and hydrides were formed due to CO2 and additional HF elimination, respectively. Beyond targeted analysis, a screening for PFAS was possible using group-specific fragments. Typical EI fragments were m/z 131 (CF2CFCF2+) for perfluoroalkenes, m/z 95 ([CF2(CH2)2OH]+) for fluorotelomer alcohols (FTOHs), and m/z 69 (CF3+) for nearly all PFAS. Typical fragments for hydrides were m/z 51 (CF2H+) and m/z 101 (CF3CFH+). Thermal extraction was done at 250 °C in a TD oven. Twenty cookware samples including baking trays, frying pans, baking mats and lab-made coating strips were investigated. No PFAS were detected in twelve samples (limits of detection (LODs): 1-13 ng/dm2). PFCAs (chain length: C5, C14-C23) were determined in a baking tray in individual amounts of up to 34 ng/dm2 (total 197 ng/dm2) and perfluorooctanoic acid (PFOA) in a baking mat at 3 ng/dm2 (all PFCAs measured as their degradation products: perfluoroalkenes). FTOHs were not detected in the samples. The PFECA perfluoro-2,5-dimethyl-3,6-dioxaheptanoic acid was quantified at 554 ng/dm2 in one coating intended for use in frying pans. Hydrides of the PFECA mixture Krytox were found in five baking trays in amounts of up to 2697 ng/dm2. None of the targeted PFAS were detectable in the five investigated frying pans. During screening for other VOC in the emissions of coatings, 175 compounds were identified including alkanes, alkenes, aromatic substances, esters, aldehydes, ketones, ethers, alcohols, carboxylic acids, siloxanes and sulphur-, nitrogen-, as well as chlorine-containing compounds (< 10 µg/dm2). The identified substances couldn’t be directly linked to the basic coating polymer of the kitchenware articles, which were PTFE and polyether sulfone (PES). All samples were subjected to a threefold thermal extraction. During the second and third consecutive extraction, no substances were above the LOD, concluding that a removal and no new formation of the investigated PFAS as well as the further VOC at 250 °C has occurred. Based on current knowledge, this is the first work presenting GC-MS measurements of several PFECAs and determining PFECAs in cookware articles. TD-GC-MS enables the detection of various volatile PFAS and PFAS degradation products as well as the performance of non-target analysis, which makes it a powerful method for emission testing.:Table of contents Summary V Kurzfassung VIII Table of contents X 1 General Introduction 1 1.1 Food contact materials 1 1.1.1 Definition and Regulations 1 1.1.2 Risk assessment 2 1.1.3 Volatile organic compounds 3 1.2 Paper and board 3 1.2.1 Production process 3 1.2.2 VOC and their origin 4 1.2.3 Analysis of VOC 6 1.2.4 Influence of relative humidity 10 1.2.5 Aims 11 1.3 Fluoropolymer-based cookware coatings 12 1.3.1 PFAS in FCMs 12 1.3.2 Production process 13 1.3.3 Toxicity and regulations of PFAS 17 1.3.4 Emission of PFAS and further VOC 18 1.3.5 Aims 23 2 Effect of rH on the desorption of (o)VOC from paper and board 24 2.1 Abstract 24 2.2 Introduction 24 2.3 Materials and methods 26 2.3.1 Samples 26 2.3.2 Chemicals 26 2.3.3 Isolation of volatile compounds by SDE 27 2.3.4 Sensory evaluation 27 2.3.5 Gravimetric analysis 28 2.3.6 Migration of VOC from paper to Tenax® 28 2.3.7 Gas chromatography – mass spectrometry (GC-MS) 30 2.3.8 Gas chromatography – olfactory detection port / flame ionization detection (GC-ODP/FID) 30 2.4 Results and discussion 31 2.4.1 Identification of odour-active substances 31 2.4.2 Sensory evaluation 35 2.4.3 Gravimetric analysis 36 2.4.4 Influence of relative humidity and temperature on the migration of VOC to Tenax® in direct contact 37 2.4.5 Influence of relative humidity, temperature and time on the migration of VOC to Tenax® in indirect contact 40 2.4.6 Comparison of indirect and direct contact between paper and Tenax in migration experiments 45 2.5 Conclusion 46 3 TD-GC-MS analysis of PFAS used in FCM 48 3.1 Abstract 48 3.2 Introduction 48 3.3 Materials and methods 50 3.3.1 Analytes 50 3.3.2 Chemicals 53 3.3.3 Hydrolysis of the methyl ester of 2,5-diMe-3,6-diO-PFHpA 53 3.3.4 Preparation and injection of standard solutions 53 3.3.5 TD-GC-MS method 54 3.4 Results and discussion 54 3.4.1 PFCAs and FTOHs 55 3.4.2 6:2 FTCA 57 3.4.3 PFECAs and PFEs 57 3.4.4 Degradation of PFCAs 65 3.4.5 LODs and LOQs 70 3.4.6 Calibration 70 3.5 Conclusion 71 3.6 Supplementary data 72 4 PFAS and further VOC from fluoropolymer-coated cookware by TD-GC-MS 74 4.1 Abstract 74 4.2 Introduction 75 4.3 Materials and methods 75 4.3.1 Chemicals 75 4.3.2 Preparation and injection of standard solutions 76 4.3.3 Deactivation of Glassware 76 4.3.4 Micro-Chamber/Thermal Extractor 76 4.3.5 Direct desorption from a pan 77 4.3.6 Thermal desorption oven 78 4.3.7 Samples 79 4.3.8 Sample preparation 79 4.3.9 TD-GC-MS method, identification and quantification 80 4.4 Results and discussion 80 4.4.1 Thermal extraction 80 4.4.2 Analysis of PFAS in a PTFE micro powder 83 4.4.3 Analysis of PFAS in cookware articles 86 4.4.4 Screening for other VOC 91 4.5 Conclusion 93 4.6 Supplementary data 94 5 General Discussion and Conclusion 96 5.1 VOC from paper and board 96 5.2 PFAS and further VOC from fluoropolymer-coated cookware 98 5.2.1 Target analysis and screening approaches of PFAS by TD-GC-MS 98 5.2.2 Thermal degradation of PFAS during TD-GC-MS measurements 100 5.2.3 Thermal extraction 103 5.2.4 Reassessment of results with regard to thermal degradation 104 5.2.5 Risk assessment 107 5.3 Future perspectives 110 References 111 Abbreviations 121 List of figures 124 List of tables 126 Publications, presentations and supervised theses 127 Publications in peer-reviewed journals 127 Oral presentations 128 Poster presentations 129 Supervised theses 129 Confirmation 130
Author: Wolf, Nancy
Language: English
Open Access status: green
OpenAlex ID: W7168444941
Cites: 139
Cited by:
Related to: 10