Abstract: Performance-based structural fire design requires an accurate representation of fire-induced thermal boundary conditions for reliable heat transfer analyses of structural elements. A widely used model for this purpose is the Eurocode Parametric Fire Curve (EPFC). While the heating phase of the EPFC is founded on a solid scientific basis, the decay and cooling phases are represented by a simplified linear decrease to ambient temperature. Moreover, the EPFC is not explicitly linked to the heat release rate (HRR) assumptions specified in Annex E of EN 1991-1-2. In this study, the HRR assumptions underpinning the EPFC are made consistent with those of Annex E of EN 1991-1-2 by modifying the duration of the heating phase. Furthermore, a probabilistic model for the decay and cooling phases is developed based on curve fitting of the adiabatic surface temperature calculated for a compartment under the well-stirred reactor assumption, using the EPFC heating phase as input for the local gas temperature. The results show that the fitting parameter, τ, can be correlated with the thermal penetration speed, v_tp, which accounts for the thermal properties of the compartment linings and the heat absorbed by these linings during the heating phase of the EPFC. An application example is presented to demonstrate the improved formulation and its practical implementation.