Work

The LHCb Beam Conditions Monitor in LHC Run 3

Year: 2026
Type: article
Abstract: At the Large Hadron Collider (LHC), the sensitive detector components of the experiments need to be protected against adverse beam conditions. Thus, the beam conditions have to be closely monitored at multiple locations along the collider. At the LHCb experiment, the Beam Conditions Monitor (BCM) is mounted around the beam pipe at two stations, upstream and downstream of the interaction point. It is built of 8 polycrystalline diamond sensors per station and integrated into the LHC Beam Interlock System to trigger beam dumps if unsafe beam conditions are detected. The BCM system has operated reliably during LHC Run 1 and 2. During the Long Shutdown 2, the LHCb detector underwent a major upgrade to maintain its performance in Run 3 at a fivefold instantaneous luminosity with respect to Run 2. Within this upgrade, the BCM was equipped with new diamond sensors and a new FPGA-based readout system. Additionally, the mechanical support of the BCM upstream station was adjusted to allow for the installation of the PLUME luminometer. After installation of the new sensors and mechanical support, the new readout system was commissioned in 2023. In total, the BCM induced six beam dumps from 2022 to 2025. This proceeding gives an overview of the upgraded BCM detector and its performance during Run 3 operation until 2025.
Language: English
Open Access status: hybrid
Estimated APC paid: $2,620
OpenAlex ID: W7172397232
FWCI:
Cites: 14
Cited by:
Related to: 10