An Analytical Study of the Basic Characteristics of Urban Gusts in the Nanjing Area and Their Influencing Factors

Year: 2025
Type: article
Abstract: Gusts are short-duration peak wind speeds observed within long-term wind speed sequences. Despite their brief nature, gusts can have extensive and significant impacts, including severe structural damage to buildings and electrical infrastructure, potentially resulting in collapse or power outages. In transportation, gusts may cause vehicle control loss or aircraft turbulence, increasing accident risks. With China's increasing urbanization, it is critical to understand the specific characteristics of urban gusts, as they play a crucial role in wind energy engineering, building safety, and transportation safety, and profoundly affect urban meteorology and environmental conditions. This research provides observational and modeling foundations for early warnings of extreme urban wind disasters and the design of wind-resistant engineering measures. This study examines the characteristics and influencing factors of gusts in urban environments, using Nanjing city as a representative study area. Initially, gust data collected from the multi-level ultrasonic anemometers (3 m, 25 m, and 50 m) installed at the Nanjing University Station for Observing Regional Processes of the Earth System (SORPES station) were analyzed statistically and characterized for winter and summer 2018. Additionally, a gust parameterization module was developed and integrated into the urban boundary layer numerical model (RBLM). Five different parameterization schemes were compared and evaluated against observational data, selecting the optimal scheme for the urban environment of Nanjing. Subsequently, sensitivity experiments were conducted for the summer 2018 case to evaluate the influence of dynamical effects, thermodynamic effects, and urban surface types on gusts. Results indicate pronounced seasonal and altitudinal variations in Nanjing’s gust characteristics. In winter, gusts near the ground, influenced by dense urban structures and cold air events, exhibited average wind speeds approximately 0.5 m/s higher and gust speeds about 0.87 m/s higher than in summer. Extreme gust events exceeding 10 m/s occurred more frequently, gust factors (GF) surpassing 2.5 comprised about 20% of occurrences, and events with amplitudes exceeding 7.5 m/s had a higher proportion, lasting approximately 6–7 seconds longer than those in summer. Conversely, during summer, mid- to upper-level gust speeds were notably higher (about 1 m/s greater), the proportion of extreme gust events over 10 m/s significantly increased, and the average spatial scale of gusts was approximately 80 m greater compared to winter. Events with spatial scales over 500 m accounted for more than 20%, highlighting significant contributions from large-scale circulation and local thermal convection at higher altitudes. Overall, seasonal meteorological conditions and altitude substantially modulate urban gust parameters. Diurnal analysis revealed that gust factors near the ground in winter typically peaked around 2.5 between 11:00 and 16:00, while in summer, peaks occurred notably during morning and evening traffic rush hours (5:00–7:00 and around 18:00). Gust factors at higher altitudes remained relatively stable but were about 0.1–0.2 higher during daytime than nighttime due to higher daytime mean wind speeds, which relatively reduced gust amplitude. With increased altitude, summer gust amplitude synchronization between different heights strengthened, with scatterplot fitting R² generally above 0.8, whereas winter data showed greater uncertainty (R² ≈ 0.58–0.85), though a certain baseline wind speed persisted at higher altitudes. The comprehensive influence of large-scale circulation, local turbulence, and building roughness on gusts became more evident with increasing altitude. Correlation analysis of gust parameters identified mean wind speed and surface shear as critical drivers for urban gusts, with correlation coefficients between friction velocity, turbulence stress, and gust parameters ranging from 0.66 to 0.85. Numerical simulations revealed that the ECMWF parameterization scheme provided the best reproduction of observed gusts in Nanjing under the RBLM framework, offering robust technical support for subsequent sensitivity analyses. Buildings significantly modulated local wind fields and thermal conditions: their removal increased gust and mean wind speeds by approximately 0.2–1.0 m/s and 0.35–0.4 m/s, respectively, while reducing turbulence intensity and the urban heat island effect, lowering urban center air and surface temperatures by approximately 0.06–0.12℃. By subtracting the “With City, No Buildings” scenario from the “No City” scenario, the isolated influence of urban thermodynamic effects on gusts and related meteorological variables was obtained. With the urban thermodynamic effect removed, gust wind speeds in the city center decreased by 0.8–1.6 m/s, while mean wind speeds increased by 0.9–1.8 m/s and gust factors fell by 0.9–1.8. During the same period, surface temperatures and near-surface air temperatures in the central area declined by 3.5–5.0 °C and 0.8–1.2 °C, respectively; relative humidity rose by 3.0–5.5 %; however, turbulent kinetic energy locally increased by 0.03–0.15 J/kg in the urban core. Complete urban removal decreased urban gust speeds by about 0.4–1.2 m/s, significantly increased mean wind speeds by about 0.9–1.5 m/s, and notably reduced urban gust factors by approximately 1.0–1.8, highlighting the profound regulatory role of urban structures on local wind and thermal environments.
Author: Chen, Xiang
Language: English
Open Access status: green
OpenAlex ID: W7197873025
FWCI:
Cites:
Cited by:
Related to: 10