Development and Application of Noncontact Near-Infrared Spectroscopy System for Measuring Biological Tissue

Year: 2012
Type: dissertation
Abstract: The in vivo application of near-infrared spectroscopy (NIRS) for brain-activity measurements was first described by Jöbsis in 1977.Over the past 35 years, this technique has been developed as a useful tool for the clinical monitoring of tissue oxygenation, for neuroimaging studies, and for the measurement of tissue structures.Abstract 2-mm intervals).Neither the light source nor the detector contacts the tissue surface.The system was validated by using it to measure the absorption change of an absorber (which is embedded in a deep layer of a tissue-simulating phantom) while the surface-layer thickness of the phantom was changed from 1 to 12 mm.It was demonstrated that both the relative absorption change of the absorber and the absolute thickness of the surface layer can be estimated from the measured optical-density change (ΔOD) and the dependence of the ΔOD on the S-D distance, respectively.Combined with the multi-distance measurement, a dynamic phantom was developed for mimicking hemoglobin changes in the superficial and deep tissues, thus allowing us to experimentally validate the discrimination methods between the brain-scalp effects on the NIRS signal.In NIRS for monitoring brain activity and cerebral functional connectivity, the effect of the superficial tissue needs to be considered.Although some methods for determining the effect of scalp and brain have been proposed, direct validation of the methods has been difficult because the actual absorption changes are not known.In response to this problem, a dynamic phantom with two absorber layers that are independently driven by two one-axis automatic stages was developed.The phantom can be used to design any type of waveform (e.g., brain activity or systemic fluctuation) of an absorption change, which can then be reproducibly measured.To determine the effectiveness of the phantom, I used it for a multiple source-detector distance measurement.The performance of a subtraction method with a short-distance regressor was also investigated.The most accurate lower-layer change was obtained when a shortest-distance channel was used.Furthermore, when an independent component analysis was applied to the same data, the extracted components were in good agreement with the actual signals.These results demonstrated that the proposed phantom can be used for evaluating the methods of discriminating the effects of superficial tissue.Next, a noncontact optical scanning system was used for human biological tissue measurements.First, the measurement of the forearm during an ischema test, and second, the measurement of the forehead while performing a working memory task are described.The measurement results showed that the developed scanning system iii can be successfully used for human tissue measurement.Finally, I discuss the future prospects of the noncontact NIRS system and promising application.The technique should be valuable, especially for the S-D distance optimization during the initial measurement of muscle tissue, the tissue thickness determination for a layered tissue structure, fast and high density deep tissue imager using an infrared CCD camera, and pressure-free long term measurement during sleep.viii Contents
Author: 司 舟根
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W2305448093
Cites: 142
Cited by: 1
Related to: 9