Work

AI-Driven Design and Optimization of a Federated Digital-Twin Architecture for Sustainable Self-Sensing Cementitious Infrastructure: A Physics-Based Synthetic Proof-of-Concept

Year: 2026
Type: article
Abstract: Intrinsically self-sensing cementitious composites offer a promising basis for continuous structural health monitoring. Their electrical response, however, is strongly affected by reversible moisture change and freeze–thaw exposure. This study presents a computational proof-of-concept for the AI-driven design of a federated digital-twin architecture for damage identification and adaptive sensing in sustainable self-sensing cementitious infrastructure. The framework is developed and evaluated entirely in software on a physics-based synthetic testbed. At its present maturity, it is therefore a digital-twin precursor rather than an operational digital twin: it has no calibrated physical counterpart and no live, two-way data coupling, and no experimental validation is claimed. A transparent, physics-based signal generator produces fractional-change-in-resistance signals for twelve virtual CNT/biochar-functionalized LC3 and geopolymer specimens. Each passes through four progressive damage stages interleaved with wet–dry and freeze–thaw conditioning. The framework integrates a CNN-LSTM damage classifier, unsupervised domain adaptation, federated learning, reinforcement-learning-based active sensing, and quantum-inspired aggregation optimization. On three unseen virtual specimens (654 evaluation windows), the CNN-LSTM achieved 70.3% four-stage accuracy (95% Wilson confidence interval 66.7–73.7%) and a macro-F1 score of 0.650, with per-specimen accuracy ranging from 63.8% to 77.1%. It reached 85.2% (95% CI 82.3–87.7%) for the damaged-versus-undamaged decision and reduced environment-induced false alarms by 74.7% (95% CI 61.7–83.4%) relative to a calibrated threshold detector. Federated averaging was less accurate and less stable than centralized training; the 5.2 percentage-point gain from quantum-inspired aggregation lies within the resolution of the evaluation set and is not established as a real improvement. The active-sensing controller reduced measurement cost by 98.9% but detected only four of 27 damage-progression events. All sensing data are synthetic, and every interval reported here is recomputed from the evaluation counts already reported rather than obtained from additional experiments. The results therefore establish algorithmic feasibility only and identify the components requiring refinement before experimental validation.
Source: Designs
Language: English
Subfield: Pollution
Open Access status: gold
Estimated APC paid: $1,930
OpenAlex ID: W7204155100
FWCI:
Cites: 59
Cited by:
Related to: