Systematic ground-effect bias in heat transfer coefficient estimation
Year: 2026
Type: conference-paper
Abstract: Data-driven building energy models often represent the building envelope using a single effective heat transfer coefficient (HTC), implicitly assuming uniform boundary conditions. In practice, this assumption is violated because floors are thermally coupled to the ground, whose temperature differs systematically from outdoor air temperature. This work examines how omission of ground coupling introduces bias in HTC estimation. A time window-level expression for the ground-effect relative bias is derived for a simplified RC network representation and shown to depend on both the floor share of total envelope conductance and an accumulated ground-effect factor over the estimation window. The effect is then investigated using synthetic high-resolution data generated from detailed Modelica simulations of archetypal single-family houses, with 2R2C models identified on moving 21-day windows. Results show that the empirical relative bias scales systematically with floor heat-transfer share and that its seasonal variation is closely tracked by the derived ground-effect bias. At the same time, the mean bias across buildings remains close to zero, indicating cancellation between competing structural bias components. The findings show that omitted physics can produce systematic, yet interpretable parameter bias, even when predictive performance is strong, underscoring the need for bias-aware model formulations in building energy performance assessment.
Source: E3S Web of Conferences
Language: English
Subfield: Building and Construction
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W7204329583